Keysight U1733C LCR-Meter
Handheld LCR meters for inductance, capacitance and resistance
Now you can measure at frequencies as high as 100 kHz, a capability that is typically found only in benchtop meters. With the auto identification, Ai which conveniently displays component type and detailed component analysis such as Z, ESR, DCR, you can get measurements done faster. Better yet, the battery lasts up to 16 hours, ideal for testing on the go. With the Keysight U1730 series, you can perform quick, basic LCR measurements at your convenience, without burning a hole in your pocket.
- Depending on model messurement of inductance (L), capacitance (C) and resistance (R):
U1701B C meter only,
U1731C, U1732C and U1731C: LCR meter. - 4.5 digits, dual display with 11,000 (U1701B) or 20,000 (U1731C, U1732C, U1733C) counts resolution.
- U1731C: 3 test frequencies (100 Hz, 120 Hz, 1 kHz),
U1732C: 4 test frequencies (100 Hz, 120 Hz, 1 kHz, 10 kHz),
U1733C: 5 test frequencies (100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz)
selectable. Series or parallel operating mode. - Data hold, maximum, minimum and average. Relative mode.
- Tolerance mode: 1%, 5%, 10% or 20%.
- Auto calculation of phase angle, dissipation dactor and quality factor (except U1701B).
- Operation with battery, optional with power supply.
- Backlit display (except U1731C).
Model Overview
Model | Measurement function | Dissipation factor (DF), quality factor (QF) phase angle measurement |
Tolerance mode | Compare mode | Test method/frequency | Resolution | Backlit display |
U1701B | C (1000 pF to 199.99 mF) | - | 1%, 5%, 10%, 20% | 25 sets of none-volatile high/low limit settings | DC charge/discharge | 11,000 | yes |
U1731C | L (200 µH to 2000 H), C (200 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz | 20,000 | - |
U1732C | L (20 µH to 2000 H), C (20 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz, 10 kHz | 20,000 | yes |
U1733C | L (20 µH to 2000 H), C (20 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz | 20,000 | yes |
Included: Handheld device U 1733C, 9 V battery, CD with datalogging software, alligator clip leads, quick start guide, calibration certificate. Optional accessories: Transportation bag, SMD test lead, external power supply.
Agilent’s Electronic Measurement Group is now Keysight Technologies.
Don't forget to quote your name, company and phone number, so we can quickly reach you, if there are any questions from our side!
Handheld LCR meters for inductance, capacitance and resistance
Now you can measure at frequencies as high as 100 kHz, a capability that is typically found only in benchtop meters. With the auto identification, Ai which conveniently displays component type and detailed component analysis such as Z, ESR, DCR, you can get measurements done faster. Better yet, the battery lasts up to 16 hours, ideal for testing on the go. With the Keysight U1730 series, you can perform quick, basic LCR measurements at your convenience, without burning a hole in your pocket.
- Depending on model messurement of inductance (L), capacitance (C) and resistance (R):
U1701B C meter only,
U1731C, U1732C and U1731C: LCR meter. - 4.5 digits, dual display with 11,000 (U1701B) or 20,000 (U1731C, U1732C, U1733C) counts resolution.
- U1731C: 3 test frequencies (100 Hz, 120 Hz, 1 kHz),
U1732C: 4 test frequencies (100 Hz, 120 Hz, 1 kHz, 10 kHz),
U1733C: 5 test frequencies (100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz)
selectable. Series or parallel operating mode. - Data hold, maximum, minimum and average. Relative mode.
- Tolerance mode: 1%, 5%, 10% or 20%.
- Auto calculation of phase angle, dissipation dactor and quality factor (except U1701B).
- Operation with battery, optional with power supply.
- Backlit display (except U1731C).
Model Overview
Model | Measurement function | Dissipation factor (DF), quality factor (QF) phase angle measurement |
Tolerance mode | Compare mode | Test method/frequency | Resolution | Backlit display |
U1701B | C (1000 pF to 199.99 mF) | - | 1%, 5%, 10%, 20% | 25 sets of none-volatile high/low limit settings | DC charge/discharge | 11,000 | yes |
U1731C | L (200 µH to 2000 H), C (200 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz | 20,000 | - |
U1732C | L (20 µH to 2000 H), C (20 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz, 10 kHz | 20,000 | yes |
U1733C | L (20 µH to 2000 H), C (20 pF to 20 mF), R (2 Ohm to 200 MOhm) |
yes/yes/yes | 1%, 5%, 10%, 20% | - | 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz | 20,000 | yes |
Included: Handheld device U 1733C, 9 V battery, CD with datalogging software, alligator clip leads, quick start guide, calibration certificate. Optional accessories: Transportation bag, SMD test lead, external power supply.
Agilent’s Electronic Measurement Group is now Keysight Technologies.
Don't forget to quote your name, company and phone number, so we can quickly reach you, if there are any questions from our side!