▸Linecard

Acromag Product Lines - DAQ and Transmission of Sensor- and Measurement-Signals

Acromag modules for signal conditioning

Multi protocol. For the industry

  • DIN-rail mountable Ethernet/LAN digital-I/O and analog-I/O modules.
  • Industrial easily expandable modules.
  • Support Ethernet Modbus/TCP, Ethernet/IO, Profinet.

Industrial Ethernet I/O modules with various I/O channel combinations. With peer-to-peer or multi-protocol Ethernet communcation.



Rugged.Multi-Channel

  • Rugged, industral, isolated 16/32-channel analog input modules for Ethernet/LAN.
  • Stackable and DIN-rail mountable.
  • Models with optical fiber port.

EtherStax - rugged, fast and multi-channel solution for isolated data acquisition with Ethernet/LAN 10/100Base-T(X), MODbus TCP/IP, or UDP/IP.


Compact. For Industrial Use

  • Ethernet/LAN digital-I/O and analog-I/O modules, DIN-rail mountable.
  • Reliable, rugged, for industrial applications.
  • Dual Ethernet for networking, additional USB (configuration).

Rugged, flexible Ethernet-I/O modules with various I/O-channel combinations and reliable housings for remote monitoring and control in the field and SCADA.


The Acromag Product Lines: Remote-I/O, Sensor Modules, Transducers, Transmitters, Signal-Conditioning

Networking I/O Modules - Analog-I/O and Digital-I/O

Series BusWorks NT BusWorks 900EN BusWorks XT EtherStax
  DIN-rail mountable I/O modules Stackable, industrial I/O modules
Protocols Multi protocol Ethernet Modbus/TCP, Ethernet/IO, Profinet Modbus TCP/IP, Ethernet/IP Modbus TCP/IP, Ethernet/IP, Profinet Modbus TCP/IP, Modbus UDP/IP
Programming Built-in web pages via Ethernet with internet browser Built-in web pages via internet browser; save with Copy Utility USB configured with Acromag XT-SIP software; save as file and easy download Built-in web pages via internet browser; save with Copy Utility
Special features
  • Sinking or sourcing DO.
  • Peer-to-peer i2o.
  • Counter/totalizer.
  • 1 Ethernet port.
  • Multi protocol support for Ethernet Modbus/TCP, Ethernet/IO, Profinet.
  • Easy and low-cost expansion with additional NTX modules.
  • Many special features standard or coming soon.
  • 9...32 VDC power supply.
  • Operating temperature -40...+70°C.
  • CE, ATEX, UL, cUL, Cl 1 Div 2.
  • Sinking or sourcing DO.
  • Peer-to-peer i2o.
  • Counters/totalizers.
  • 16 bit signed registers.
  • 32 bit floating point registers.
  • 1 Ethernet port.
  • High speed models.
  • Watchdog timers.
  • Redundant power.
  • 1500 VAC isolation.
  • -
  • Operating temperature -25...+70°C.
  • CE, ATEX, UL, cUL, Cl 1 Div 2.
  • Sinking or sourcing DO.
  • Peer-to-peer i2o.
  • 16 bit signed registers.
  • 2 Ethernet ports.
  • High speed models.
  • Watchdog timers.
  • Redundant power.
  • 1500 VAC isolation.
  • 25 G shock, 4 G vibration.
  • Operating temperature -40...+70°C.
  • CE, ATEX, UL, cUL, Class 1 Div 2.
  • Sinking DO and relay outputs.
  • Peer-to-peer i2o.
  • Counters/totalizers.
  • 16 bit signed registers.
  • 32 bit floating point registers.
  • 2 Ethernet ports - switch or hub.
  • High speed models.
  • Watchdog timers.
  • Redundant power.
  • 1500 VAC isolation.
  • 50 G shock, 5 G vibration.
  • Operating temperature -40...+75°C.
  • CE, UL, cUL, Class 1 Div 2.

Signal Transmitters

Series microBlox µB Series 600 Series IntelliPack 800 Series TT230 and TT330 Series, ST Series
Description The new generation of modular, reliable signal conditioning. Models with bluetooth configuration Industrial signal-conditioning and isolators: 600T and 800T transmitters, isolators, splitters 800A alarm modules 800M math/computing modules TT Series: Very compacte temperature transmitters with USB configuration ST Series: Mini temperature transmitters for RTD or thermocouples, for 4...20 mA current loop
Configuration Depending on version: Fix/not required or via Bluetooth Manually set-up Software to program or factory set-up Ready to use with default settings, software to program, or factory set-up
Transmitter inputs Common signal and sensor types Current isolators and splitters, voltage, thermocouple, RTD, AC current Current, voltage, thermocouple, RTD, strain gauge/load cell, frequency, AC current Current, voltage, thermocouple, RTD, potentiometer/thermistor, frequency, AC current
Special features
  • Up to 16 modules individually combined on a module carrier.
  • High reliability and safety with channel-to-channel isolation.
  • Bandwidth 5 Hz.
  • Android/iOS App for configuration of the Bluetooth version.
  • Wide choice of modul/signal types.
  • Digital zero/span for easy setup.
  • 1, 2 and 4 channel units.
  • External adjustments for calibation.
  • Sinking current outputs.
  • 611T/612T V/I both in and out.
  • Splitters: Output loop powered, 24 VDC and 115 VAC powered.
  • Thermocouple splitter unit.
  • 1500 VAC isolation.
  • Operating temperature -25...+75°C.
  • CE, UL, cUL, Class 1 Div 2.
  • Windows programming via RJ11 port on unit.
  • External adjustments for calibration.
  • Sourcing current outputs.
  • Analog output with relay output.
  • 25 break point linearizer.
  • 6 types of alarms.
  • Math: Analog or frequency out.
  • 1500 VAC isolation.
  • Operating temperature -25...+70°C.
  • CE, UL, cUL.
  • Windows programming via USB Mini-B port on unit.
  • No external adjustments.
  • Sinking and sourcing current out.
  • Bipolar outputs: ±10 V, ±20 mA.
  • High speed/high filter units.
  • Redundant power.
  • 25 G shock, 4 G vibration.
  • 1500 VAC isolation.
  • Operating temperature -40...+80°C.
  • CE, ATEX, UL, cUL, Class 1 Div 2.
  • ST Series: Compact temperature transmitters in "puck" design for Pt RTD or thermocouples; models with isolation.

Why Signal Adaptation and Signal Transmitters?

Measurement technology in laboratory environments differs significantly from the industrial environment in many aspects. Three important points are for example:

  • Space/distances: While measurement setups in the laboratory are often possible in a relatively small space and with short measurement lines, the industrial environment of a factory floor often requires long distances and many measurement or control points distributed over a large area.
  • Environmental conditions: While "normal" room temperature usually prevails in the laboratory, or optimal conditions are created for special measurements, for example with temperature chambers, extreme climatic conditions (dust, temperature and humidity, vibration by machines, etc.) and fluctuations are often present in the industrial environment (or even outdoors).
  • Automation: While in the laboratory measurements can often be performed manually, at least partially, or individual steps can be carried out directly by an engineer or technician, in the industrial environment as much as possible must be automated. The speed and reproducibility of the measurement often play a role here, because "time is money" in the industrial process.

Industrial signal converters and transmitters are designed and optimized exactly for use in industrial environments.

  • These modules fulfill the mentioned space/distance requirement by the fact that they can be mounted close to the measuring location. The interference-prone measuring lines, for example to the sensor, can thus be kept short. In the module, the acquired signals are converted, either by A/D directly into a digital signal or into easily transmittable standard signals. The advantage is that the sensor signal is simultaneously adapted and linearized for subsequent evaluation. In addition, the modules can be networked over large areas and distances, e.g. if a LAN transmission or other bus is supported by the transmitter modules. A module takes over a measuring point with one or more inputs and/or outputs.
  • The modules also meet the requirements for adaptation to environmental conditions. This starts with aspects such as robustness (extended temperature ranges, IP standards, moulded or sealed housings, etc.). In addition, they often have a space-saving, safe and easy-to-mount design, for example bayed housings for DIN-rails. In addition, the power supply of such modules is often in a wider range including industrial standard ranges, moreover often designed redundantly and thus safer.
  • The modules meet the requirement for a high degree of automation through their networking and coupling to a central, controlling computer. The data collected by the module is processed by this computer and, if necessary, actuators are controlled by a module in response.

As a supplement Acromag offers...

  • Isolators, with which a transmission can be galvanically isolated. This provides more safety against voltage peaks and prevents ground loops caused by potential differences.
  • Splitters and Math modules, with which signals can be split into several paths or mathematically combined.
  • Alarms, with which an alarm is triggered when defined limit values are exceeded, for example in the form of a relay being switched.

Get in Contact with the Meilhaus Electronic Team:

 Phone: +49(0)8141/5271-0
 E-Mail
 Newsletter