CAMI/CableEye Test System for Cables and Wire Harnesses

CableEye tester for cables and cable harnishes

  • CableEye accompanies you in all "life phases" of your cables. From the first design of new cables and prototypes to production, quality control/final test and daily use when reliable cables are required.
  • CableEye is modular expandable and future-proof. From 128 up to 2560 test points. For testing of connection/continuity/line break, cable allocation/miswiring, resistance, insulation resistance, sporadically occurring errors and much more.
  • CableEye provides the perfect test protocols for quality assurance and quality control.

Test and Measurement Matrix

Model ▸M2Z ▸M3Z ▸M4 ▸HVX ▸HVX-21
Continuity Opens, shorts, miswires
Intermittent faults
Complex networks, backplanes
Resistance Connection, non-Connection quality
Resistance (2-wire)
Continuous resistance scan
Fixture resistance nulling
Resistance (4-wire Kelvin) (✓) option (✓) option
High current resistance (✓) option (✓) option
Capacitance Wire length, cable length (✓) option (✓) option
Length to break (✓) option (✓) option
Twist pairing (✓) option (✓) option
Single channel safety test Chassis, panels, transformers, etc.
Insulation quality Dielectric strength, withstand voltage
Insulation resistance
Presence of contaminants
In-Line Components Resistors
Diodes - orientation
Diodes - forward voltage
LEDs - orientation
LEDs - color detection
Zener diodes - orientation
Zener diodes - forward voltage
Zener diodes - reverse breakdown voltage <10 V
Zener diodes - reverse breakdown voltage >10 V
Capacitors (✓) option (✓) option

Model Overview and Features

Model Low voltage Low voltage Low voltage High voltage High voltage Model
▸MZ ▸M3Z ▸M4 ▸HVX ▸HVX-21
▸CAMI-814 ▸CAMI-826 ▸CAMI-824 ▸CAMI-829 ▸CAMI-829A
Control module test points 128 128 + 24 accessory test points 128 + 24 accessory test points 128 + 24 accessory test points for LV tests, 128 for HV tests 128 + 24 accessory test points for LV tests, 128 for HV tests Control module test points
Max. test points 128 2560 2560 1024 512 Max. test points
Test time (128 test points) - continuity only 0.20 s 0.15 s 0.15 s From 0.20/0.15 s From 0.20/0.15 s Test time (128 test points) - continuity only
Test time (128 test points) - with resistance test N/A 0.40 s 0.40 s From 0.25/0.40 s From 0.25/0.40 s Test time (128 test points) - with resistance test
Resistance thresholds 46 kΩ, fixed 0.1 Ω...5 MΩ 0.02 Ω...6 MΩ 0.1/0.02 Ω...1 GΩ 0.1/0.02 Ω...5 GΩ Resistance thresholds
Resistance accuracy - 10Ω...100Ω - ±0.2Ω ±0.15Ω ±0.2Ω/±0.15Ω ±0.2Ω/±0.15Ω Resistance accuracy - 10Ω...100Ω
Resistance accuracy - 100Ω...1MΩ - 1% 1% 1...5% (1...100 MΩ) 1...5% (1...100 MΩ) Resistance accuracy - 100Ω...1MΩ
Resistance accuracy - full range - Lesser accuracy over full range Lesser accuracy over full range Lesser accuracy above 100 MΩ Lesser accuracy above 100 MΩ Resistance accuracy - full range
Resistance Range - 0.1 Ω...5 MΩ 0.02 Ω...6 MΩ 0.1/0.02 Ω...5/6 MΩ 0.1/0.02 Ω...5/6 MΩ Resistance Range
4-Wire Kelvin - - 20 mΩ ± 20 mΩ (20 mΩ...15 Ω, test current 3.3 mA 1 mΩ ±1 mΩ (1 mΩ...15 Ω, test current 100 mA...1 A) - optional feature (item 832) 1 mΩ ±1 mΩ (1 mΩ...15 Ω, test current 100 mA...1 A) - optional feature (item 832) 4-Wire Kelvin
Intermittent connection scan rate 33 Scans/s 18 Scans/s - 128 test points, 47 Scans/s - 64 test points 18 Scans/s - 128 test points, 47 Scans/s - 64 test points 90 Scans/s - 64 test points, 47 Scans/s - 64 test points 90 Scans/s - 64 test points, 47 Scans/s - 64 test points Intermittent connection scan rate
Diode measurement Orientation only Orientation, forward voltage and reverse breakdown <10 V Orientation, forward voltage and reverse breakdown <10 V Orientation, forward voltage and reverse breakdown >10 V Orientation, forward voltage and reverse breakdown >10 V Diode measurement
Test voltage 5 V 10 V Adjustable: 1.7/2.5/3.3/5/10 V 10...1500 VDC or 10...1000 VACRMS in increments of 1 V 10...2100 VDC or 10...1200 VACRMS in increments of 1 V Test voltage
Test voltage accuracy - - - DC: ±2%, ±1.5 V; AC: ±4%, ±2VRMS DC: ±2%, ±1.5 V; AC: ±4%, ±2VRMS Test voltage accuracy
Max. test current 0.3 mA 3.3 mA 3.3 mA 3.3 mA 3.3 mA Max. test current
Capacitance range - - 100 pF...100 mF 100 pF...100 mF - optional feature (item 833) 100 pF...100 mF - optional feature (item 833) Capacitance range
Capacitance accuracy - - ±5% ±5% - optional feature (item 833) ±5% - optional feature (item 833) Capacitance accuracy
Capacitance measurement rate - - 20 Meas./s at 100 nF or less 20 Meas./s at 100 nF or less - optional feature (item 833) 20 Meas./s at 100 nF or less - optional feature (item 833) Capacitance measurement rate
Twisted pair measurement - - Yes, 182.9 cm/6 ft min. length Yes, 182.9 cm/6 ft min. length - optional feature (item 833) Yes, 182.9 cm/6 ft min. length - optional feature (item 833) Twisted pair measurement
Measurement cable length - - Min. length 182.9 cm/6 ft, ±91.4 cm/3 ft Min. length 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833) Min. length 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833) Measurement cable length
Measurement distance to break - - Min. distance to break 182.9 cm/6 ft, ±91.4 cm/3 ft Min. distance to break 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833) Min. distance to break 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833) Measurement distance to break
Dwell time range 1 µs...100 ms 1 µs...100 ms 1 µs...100 ms LV: 1 µs...100 ms; HV: 30 ms...300 s LV: 1 µs...100 ms; HV: 30 ms...300 s Dwell time range
Insulation resistance measurement - 5 MΩ at 10 V 6 MΩ at 10 V 2 MΩ...1 GΩ at 1500 VDC; 2 MΩ (min.) at 1000 VAC; current sensitivity: 1 µA 2 MΩ...5 GΩ at 100 VDC; 2 MΩ (min.) at 1200 VAC; current sensitivity: 0.2 µA Insulation resistance measurement
Digital-I/Os Inputs only Pairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765) Pairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765) Pairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765) Pairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765) Digital-I/Os
Calibration Not required Recommended yearly Recommended yearly Recommended yearly Recommended yearly Calibration
Test point connectors 64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module 64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module 64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module 64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module 64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module Test point connectors
Remote control socket No Yes, MiniDIN8 Connector for use with e.g. footswitch, external control panel Yes, MiniDIN8 Connector for use with e.g. footswitch, external control panel Yes, MiniDIN8 Connector for use with e.g. footswitch, external control panel Yes, MiniDIN8 Connector for use with e.g. footswitch, external control panel Remote control socket
Probe socket No Yes; probe included with tester; accessory port also usable with minihook cables Yes; probe included with tester; accessory port also usable with minihook cables Yes; probe included with tester; accessory port also usable with minihook cables Yes; probe included with tester; accessory port also usable with minihook cables Probe socket
Power requirement 9 VDC/300 mA (max.)/3 W, from wall module 18 VDC/500 mA (max.)/9 W, from wall module or desktop supply 18 VDC/500 mA (max.)/9 W 100...250 VAC, 50...60 Hz/130 W (max.) for 128 test points; 175 W (max.) for 512 test points; IEC-standard universal C14 chassis plug 100...250 VAC, 50...60 Hz/130 W (max.) for 128 test points; 175 W (max.) for 512 test points; IEC-standard universal C14 chassis plug Power requirement
Weight 1.12 kg 1.2 kg 1.1 kg 9.5 kg 9.5 kg Weight
Computer requirements Any Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs Any Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs Any Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs Any Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs Any Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs Computer requirements
USB interface USB 1.1, fast USB 1.1, fast USB 1.1, fast USB 1.1, fast, two ports USB 1.1, fast, two ports USB interface

Compatibility Between CB Boards and CableEye Testers

A green checkmark denotes that the CB board is compatible with the tester displayed in the column.
A red x denotes that the CB board is NOT compatible with the tester displayed in the column.
A number in the "Expansions Required" column means that the tester requires the number of expansion modules displayed to use the board.
Only for the HVX High Voltage testers, the "Voltage Rating" column displays the maximum voltage that the board can sustain without dielectric breakdown.

CB Board M2Z, M2U Basic* M2U*, M3U*, M3Z, M4, HVX Expansions Required Voltage Rating
▸CB1 500
▸CB2 500
▸CB2A 500
▸CB3 500
▸CB4 500
▸CB5 500
▸CB6 500
▸CB7 1 500
▸CB8 500
▸CB9 500
▸CB10 1 500
▸CB11 500
▸CB12 60 conductors max. 60 conductors max. 1 500
▸CB12A 60 conductors max. 60 conductors max. 1 500
▸CB13 500
▸CB14 500
▸CB15 500
▸CB16 500
▸CB16A 500
▸CB17 500
▸CB18 500
▸CB18A 500
▸CB18B 500
▸CB18C 500
▸CB19 500
▸CB20 1 500
▸CB21 1 500
▸CB22 500
▸CB23 500
▸CB24 1 500
▸CB25 500
▸CB25A 500
▸CB25B 500
▸CB26A 500
▸CB26B 500
▸CB26C 500
▸CB26D 500
▸CB26E 500
▸CB26F 500
▸CB26G 500
▸CB26H 500
▸CB26I 500
▸CB26K 500
▸CB26L 500
▸CB26M 500
▸CB26N 500
▸CB26T 500
▸CB27 500
▸CB28 500
▸CB29 500
▸CB29A 500
▸CB29H 500
▸CB29HA 500
▸CB29BB 500
▸CB30 1 500
▸CB30A 1 500
▸CB30B 2 500
▸CB30C 2 500
▸CB31 1 500
▸CB32 1 500
▸CB33 500
▸CB34 500
▸CB35 500
▸CB37A M3U*, M3Z, M4, HVX 500
▸CB38A M3U*, M3Z, M4, HVX 1 500
▸CB39 500
▸CB40 500
▸CB41 500
▸CB42 500
▸CB43 500
▸CB44 500
▸CB45 500
▸▸CB46 1 500
▸CB47 500
▸CB48A 500
▸CB48B 500
▸CB49 500
▸CB50 M3U*, M3Z, M4, HVX 500
▸CB-T1 500

* EOL/obsolete.