Ceyear 3674 Series Vector Network Analyzer 10MHz to 110GHz
Benefits of the Series 3674 High-end 2- and 4-port VNAs
- VNAs with 2- or 4-ports, 10 MHz to 110 GHz.
- Dynamic range up to 140 dB, 30 MHz IF bandwidth.
- 15.6"/39.6 cm touch-screen; USB and LAN/Ethernet interfaces.
Ceyear 3674 Series Vector Network Analyzer 10 MHz to 110 GHz
The Ceyear 3674 family is a series of high-end vector network analyzers up to 110 GHz. It was designed to deal with the severe challenges brought by semiconductor chip testing, material testing, antenna testing, high-speed cable testing, and microwave component testing and so etc. Excellent RF characteristics, flexible hardware configuration and rich software functions complement each other. The large touch-screen allows a flexible and efficient operation, the interfaces make integration into test systems easy.
- Highend vector network analyzers (VNAs) with 2 or optional 4 ports and a 500 Hz up to 110 GHz broad band coaxial coverage.
- 30 MHz IF bandwidth, measurement points 200001.
- Ultra-fast scanning speed, high measurement accuracy, 140 dB large dynamic range.
- 21 functions, such as pulse S-parameter measurement, frequency conversion device measurement, gain compression measurement, noise coefficient measurement, frequency spectrum measurement, signal integrity measurement, total harmonic distortion measurement, active intermodulation distortion measurement, and automatic fixture removal.
- Excellent pulse test capability:
- Pulse period of up to 70 s.
- Pulse resolution as low as 8.3 ns.
- Broadband synchronous pulse test pulse width <42 ns.
- Internal pulse synchronization or external pulse synchronization mode.
- 7 source modulation modes, such as external and internal pulses.
- 4 pulse generators with pulse width and independent delay.
- Automatic broadband synchronous measurement and narrow-band asynchronous measurement function.
- Adaptive narrow-band filter to improve the narrow-pulse test capability
- 3 for triggering input and output modules to provide flexible system coordination function.
- Functions of sweeping pulse S parameter test, pulse envelope test and pulse point test.
- SCPI instruction synchronization record, script generated with one key
- 15.6"/39.6 cm multi-parameter display on the same screen, with multi-touch operation.
Model Overview
| Model | 3674B | 3674C | 3674D | 3674E | 3674F | 3674G | 3674H | 3674K | 3674L | 3674N | 3674P |
| Frequency range | 10 MHz...9 GHz | 10 MHz...14 GHz | 10 MHz...20 GHz | 10 MHz...26.5 GHz | 10 MHz...32 GHz | 10 MHz...44 GHz | 10 MHz...50 GHz | 10 MHz...53 GHz | 10 MHz...67 GHz | 10 MHz...90 GHz | 10 MHz...110 GHz |
| Frequency resolution | 0.1 Hz | 0.1 Hz | 0.1 Hz | 0.1 Hz | |||||||
| System dynamic range (standard configuration, typ.) | 108 dB (10 MHz...50 MHz) 124 dB (50 MHz...500 MHz) 140 dB (0.5 GHz...4 GHz) 140 dB (4 GHz...14 GHz) 133 dB (14 GHz...20 GHz) 128 dB (20 GHz...26.5G Hz) | 104 dB (10 MHz...50 MHz) 122 dB (50 MHz...500 MHz) 137 dB (0.5 GHz...4 GHz) 139 dB (4 GHz...14 GHz) 138 dB (14 GHz...20 GHz) 138 dB (20 GHz...26.5 GHz) 133 dB (26.5 GHz...40 GHz) 130 dB (40 GHz...47 GHz) 111 dB (47 GHz...50 GHz) | 102 dB (10...50 MHz) 124 dB (50...500 MHz) 137 dB (0.5...4 GHz) 142 dB (4...14 GHz) 138 dB (14...26.5 GHz) 134 dB (26.5...40 GHz) 128 dB (40...50 GHz) 118 dB (50...60 GHz) 116 dB (60...67 GHz) | 70 dB (10 MHz...500 MHz) 105 dB (0.5 GHz...1 GHz) 110 dB (1 GHz...26.5 GHz) 107 dB (26.5 GHz...50 GHz) 90 dB (50 GHz...72 GHz) 100 dB (72 GHz...90 GHz) 90 dB (90 GHz...110 GHz) 80 dB (110 GHz...120 GHz) | |||||||
| Number of measurement ports | Standard: 2; option -400: 4 | Standard: 2; option -400: 4 | Standard: 2; option -400: 4 | Standard: 2; option -400: 4 | |||||||
| Trace noise | Trace noise magnitude (1 kHz IF bandwidth, typ.) | Trace noise magnitude (1 kHz IF bandwidth, typ.) | Trace noise magnitude (1 kHz IF bandwidth, typ.) | Trace noise magnitude (1 kHz IF bandwidth, typ.) | |||||||
| 0.0026 dBRMS (10...100 MHz) 0.0017 dBRMS (100...500 MHz) 0.0006 dBRMS (0.5...1 GHz) 0.0006 dBRMS (1...14 GHz) 0.0007 dBRMS (14...22.5 GHz) 0.0008 dBRMS (22.5...24 GHz) 0.0007 dBRMS (24...26.5 GHz) | 0.0039 dBRMS (10...50 MHz) 0.0006 dBRMS (50...500 MHz) 0.0005 dBRMS (0.5...1 GHz) 0.0006 dBRMS (1...26.5 GHz) 0.0007 dBRMS (26.5...44 GHz) 0.0008 dBRMS (44...50 GHz) | 0.0042 dBRMS (10...50 MHz) 0.0030 dBRMS (50...100 MHz) 0.0006 dBRMS (100...500 MHz) 0.0004 dBRMS (0.5...1 GHz) 0.0003 dBRMS (1...26.5 GHz) 0.0009 dBRMS (26.5...50 GHz) 0.0077 dBRMS (50...67 GHz) | 0.200 dBRMS (10 MHz...100 MHz) 0.007 dBRMS (0.1 GHz...26.5 GHz) 0.004 dBRMS (26.5 GHz...50 GHz) 0.007 dBRMS (50 GHz...110 GHz) 0.009 dBRMS (110 GHz...120 GHz) | ||||||||
| Trace noise phase (1 kHz IF bandwidth, typ.) | Trace noise phase (1 kHz IF bandwidth, typ.) | Trace noise phase (1 kHz IF bandwidth, typ.) | Trace noise phase (1 kHz IF bandwidth, typ.) | ||||||||
| 0.030° RMS (10...100 MHz) 0.012° RMS (100...500 MHz) 0.004° RMS (0.5...1 GHz) 0.004° RMS (1...14 GHz) 0.005° RMS (14...22.5 GHz) 0.005° RMS (22.5...24 GHz) 0.005° RMS (24...26.5 GHz) | 0.024° RMS (10...50 MHz) 0.004° RMS (50...500 MHz) 0.003° RMS (0.5...1 GHz) 0.004° RMS (1...26.5 GHz) 0.005° RMS (26.5...44 GHz) 0.005° RMS (26.5...50 GHz) | 0.029° RMS (10...50 MHz) 0.008° RMS (0.05...26.5 GHz) 0.008° RMS (26.5...50 GHz) 0.051° RMS (50...67 GHz) | not specified | ||||||||
| IFBW | 1 Hz...30 MHz | 1 Hz...30 MHz | 1 Hz...30 MHz | 1 Hz...30 MHz | |||||||
| Port connector | 3.5 mm (head), system impedance 50 Ω | 2.4 mm (head), system impedance 50 Ω | 1.85 mm (head), system impedance 50 Ω | 1.0 mm (head), system impedance 50 Ω | |||||||
| Display | 15.6"/39.6 cm high-resolution touch display; DP interface | 15.6"/39.6 cm high-resolution touch display; DP interface | 15.6"/39.6 cm high-resolution touch display; DP interface | 15.6"/39.6 cm high-resolution touch display; DP interface | |||||||
| Interfaces | USB, LAN/Ethernet, GPIB | USB, LAN/Ethernet, GPIB | USB, LAN/Ethernet, GPIB | USB, LAN/Ethernet, GPIB | |||||||
| Dimensions (WxHxD, mm, overall) | 2-port: 475 x 279 x 560; 4-port: 475 x 279 x 660; 50 kg | 2-port: 475 x 279 x 560; 4-port: 475 x 279 x 660; 50 kg | 2-port: 475 x 279 x 560; 4-port: 475 x 279 x 660; 50 kg | 2-port: 475 x 279 x 560; 4-port: 475 x 279 x 660; 50 kg; PA, QA: 84 kg | |||||||
3674PA Vector Network Analyzer (10 MHz...110 GHz) System Configuration
| Name | Configuration, 2-port model | Configuration, 4-port model |
| Vector network analyzer and options | 3674E/F/G/H/K/L + S20 | 3674E/F/G/H/K/L + 400 + S20 |
| Millimeter wave test set | 3674-009 | 3674-010 |
| Coaxial frequency extender | 3674-011 (quantity 2) | 3674-011 (quantity 4) |
Included: Ceyear VNA 3647 B, C, D, E, F, G, H, K, L, N, or P, power cord, USB mouse, quick operation guide, certificate of conformity, Aluminum alloy box.
Ceyear 3647 Series Options and Accessories
| Model | Description | For VNA... |
| 3674-006 | English version option - English front and rear panel, English operating system | All models |
| 3674-007 | Linux operating system, to replace the Windows operating system | All models |
| 3674-009 | 2-port millimeter wave test set - used to expand the frequency of the 2-port vector network analyzer; requires option 3674-S20 | 2-port |
| 3674-010 | 4-port millimeter wave test set - used to expand the frequency of the 4-port vector network analyzer; requires option 3674-S20 | 4-port |
| 3674-011 | 110 GHz coaxial frequency extender, for vector network analyzer frequency expansion to achieve coaxial S parameter measurement from 10 MHz...110 GHz. The second port requires two modules and the four modules; 2-port requires options 3674-009, 3674-S20; 4-port requires options 400 + 3674-010 + 3674-S20 | |
| 3674-S05 | S-parameter signal integrity analysis function; the signal integrity characteristics, such as frequency domain, time domain TDR and crosstalk, can automatically convert the graph curve into a test report | All Models |
| 3674-S07 | Automatic fixture removal function (AFR), for automatic testing and removal of single-end and balance device measuring fixture | All Models |
| 3674-S10 | Time domain measurement function; determine and analyze the discontinuous positions in devices, fixtures, or cables | All models |
| 3674-S11 | Advanced time domain analysis function; for TDR time-domain impedance testing, eye-map analysis, etc. | All models |
| 3674-S16 | True difference measurement function and common mode excitation balance parameters measurement; requires options 400 + 404 + 3674-S28 | 3674B/C/D/E/F/G/H/K/L |
| 3674-S18 | Fast CW sweep function; data is read immediately using the FIFO buffer method | All models |
| 3674-S20 | Frequency offset measurement function | All models |
| 3674-S22 | Mixer/converter scalar parameter measurement; requires options 400 + S20 | 3674B/C/D/E/F/G/H/K/L |
| 3674-S24 | Embedded LO frequency converter measurement; used for embedded local vibration converter measurement; requires options 400 + S20 + S22/023 | 3674B/C/D/E/F/G/H/K/L |
| 3674-S26 | Gain compression measurement for active devices such as amplifiers | 3674B/C/D/E/F/G/H/K/L |
| 3674-S28 | Phase-scan measurement; requires option 400 | For 3674B/C/D/E/F/G/H/K/L |
| 3674-S29 | Differential I/Q measurement; testing differential and I/Q mixers, amplifiers, etc. It can measure the frequency conversion loss or gain, LO feedthrough, oscillator isolation, differential harmonics, total harmonic distortion (THD), and image rejection of the measured device under differential or I/Q excitation. It supports arbitrary phase, power, and frequency customization for measurement. The optional accessories include 400 + S20 + S28 | 3674B/C/D/E/F/G/H/K/L |
| 3674-042 | Millimeter wave test; set-waveguide frequency; extender bundle cable; for the vector network analyzer waveguide expansion system, the spread frequency controller interconnects with the waveguide spread spectrum module, including two ports and four ports. Configure two sets of 2-port and 4 sets of 4-port | |
| 3674-043 | 4-port frequency extension system cable; used for 4-port vector network analyzer and waveguide spread frequency module | 3674E |
| 3674-044 | 4-port frequency extension system cable; used for 4-port vector network analyzer and waveguide spread frequency module | 3674F/G/H |
| 3674-045 | 4-port frequency extension system cable; used for 4-port vector network analyzer and waveguide spread frequency module | 3674K/L |
| 3674-061 | Extension table for test desktop; extension for the test, length and width 500 mm/350 mm | All models |
| 3674-062 | Rack mount kit | All models |
| 3674-063 | Printed user manual (English) | All models |
| 3674-GZ | Product modification service - this option is required when you add hardware options after returning to the factory for upgrade | All models |
| 3674B-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674B-201 + 3674B-204 4-port requires options 3674B-401 + 3674B-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately | 3674B |
| 3674B-008 | Pulse measurement; for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674B |
| 3674B-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674B-400 + 3674B-404 + 3674-S20 | 3674B |
| 3674B-201 | 2-port programmable step attenuator: 2...70 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674B-204 | 3674B |
| 3674B-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674B-204; 3674B-205 cannot be configured at the same time | 3674B |
| 3674B-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674B |
| 3674B-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage: require options 3674B-201 + 3674B-204; 3674B-203 cannot be configured at the same time | 3674B |
| 3674B-400 | 4-port measurement; dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...9 GHz | 3674B |
| 3674B-401 | 4-port programmable step attenuator: 4...70 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674B-400 + 3674B-404 | 3674B |
| 3674B-402 | Active intermodulation distortion measurement; requires options 3674B-400 + 3671B-404 + 3674-S20 | 3674B |
| 3674B-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 requires options 3674B-400 + 3674B-404; 3674B-405 cannot be configured at the same time | 3674B |
| 3674B-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; require option 3674B-400 | 3674B |
| 3674B-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674B-400 + 3674B-401 + 3672B-404; 3674B-403 cannot be configured at the same time | 3674B |
| 3674B-S30 | Spectrum analysis function/multichannel spectrum testing | 3674B |
| 3674C-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674C-201 + 3674C-204; 4-port requires options 3674C-401 + 3674C-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately) | 3674C |
| 3674C-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674C |
| 3674C-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674C-400 + 3674C-404 + 3674-S20 | 3674C |
| 3674C-201 | 2-port programmable step attenuator: 2...70 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674C-204 | 3674C |
| 3674C-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674C-204; 3674C-205 cannot be configured at the same time | 3674C |
| 3674C-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674C |
| 3674C-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674C-201 + 3674C-204; 3674C-203 cannot be configured at the same time | 3674C |
| 3674C-400 | 4-port measurement dual source excitation 4-port vector network analyzer configuration with frequency range 10 MHz...14 GHz | 3674C |
| 3674C-401 | 4-port programmable step attenuator: 4...70 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674C-400 + 3674C-404 | 3674C |
| 3674C-402 | Active intermodulation distortion measurement; requires options 3674C-400 + 3674C-404 + 3674-S20 | 3674C |
| 3674C-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 requires options 3674C-400 + 3674C-404; 3674C-405 cannot be configured at the same time | 3674C |
| 3674C-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; require option 3674C-400 | 3674C |
| 3674C-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674C-400 + 3674C-401 + 3674C-404; 3674C-403 cannot be configured at the same time | 3674C |
| 3674C-S30 | Spectrum analysis function/multichannel spectrum testing | 3674C |
| 3674D-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674D-201 + 3674D-204; 4-port requires options 3674D-401 + 3674D-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately) | 3674D |
| 3674D-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674D |
| 3674D-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674D-400 + 3674D-404 + 3674-S20 | 3674D |
| 3674D-201 | 2-port programmable step attenuator: 2...70 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674D-204 | 3674D |
| 3674D-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674D-204; 3674D-205 cannot be configured at the same time | 3674D |
| 3674D-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674D |
| 3674D-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674D-201 + 3674D-204; 3674D-203 cannot be configured at the same time | 3674D |
| 3674D-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...20 GHz | 3674D |
| 3674D-401 | 4-port programmable step attenuator: 4...70 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674D-400 + 3674D-404 | 3674D |
| 3674D-402 | Active intermodulation distortion measurement; requires options 3674D-400 + 3674D-404 + 3674-S20 | 3674D |
| 3674D-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674D-400 + 3674D-404; 3674D-405 cannot be configured at the same time | 3674D |
| 3674D-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674D-400 | 3674D |
| 3674D-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires option 3674D-400 + 3674D-401 + 3674D-404; 3674D-403 cannot be configured at the same time | 3674D |
| 3674D-S30 | Spectrum analysis function/multichannel spectrum testing | 3674D |
| 3674E-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674E-201 + 3674E-204; 4-port requires options 3674E-401 + 3674E-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately | 3674E |
| 3674E-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674E |
| 3674E-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires options 3674E-400 + 3674E-404 | 3674E |
| 3674E-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674E-400 + 3674E-404 + 3674-S20 | 3674E |
| 3674E-201 | 2-port programmable step attenuator: 2...70 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674E-204 | 3674E |
| 3674E-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674E-204; 3674E-205 cannot be configured at the same time | 3674E |
| 3674E-204 | Configurable test set expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674E |
| 3674E-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674E-201 + 3674E-204; 3674E-203 cannot be configured at the same time | 3674E |
| 3674E-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with frequency range 10 MHz...26.5 GHz | 3674E |
| 3674E-401 | 4-port programmable step attenuator: 4...70 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674E-400 + 3674E-404 | 3674E |
| 3674E-402 | Active intermodulation distortion measurement; requires options 3674E-400 + 3674E-404 + 3674-S20 | 3674E |
| 3674E-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674E-400 + 3674E-404; 3674E-405 cannot be configured at the same time | 3674E |
| 3674E-404 | Configurable test set expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674E-400 | 3674E |
| 3674E-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674E-400 + 3674E-401 + 3674E-404; 3674E-403 cannot be configured at the same time | 3674E |
| 3674E-S30 | Spectrum analysis function/multichannel spectrum testing | 3674E |
| 3674F-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674F-201 + 3674F-204; 4-port requires options 3674F-401 + 3674F-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately | 3674F |
| 3674F-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674F |
| 3674F-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires option 3674F-400 + 3674F-404 | 3674F |
| 3674F-023 | Mixer/converter vector for the mixer-based vector parameter measurement; requires options 3674F-400 + 3674F-404 + 3674-S20 | 3674F |
| 3674F-201 | 2-port programmable step attenuator: 2...60 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674F-204 | 3674F |
| 3674F-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674F-204; 3674F-205 can not be configured at the same time | 3674F |
| 3674F-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674F |
| 3674F-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674F-201 + 3674F-204; 3674F-203 cannot be configured at the same time | 3674F |
| 3674F-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...32 GHz | 3674F |
| 3674F-401 | 4-port programmable step attenuator: 4...60 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674F-400 + 3674F-404 | 3674F |
| 3674F-402 | Active intermodulation distortion measurement; requires options 3674F-400 + 3674F-404 + 3674-S20 | 3674F |
| 3674F-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674F-400 + 3674F-404; 3674F-405 cannot be configured at the same time | 3674F |
| 3674F-404 | Configurable test set expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674F-400 | 3674F |
| 3674F-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674F-400 + 3674F-401 + 3674F-404; 3674F-403 cannot be configured at the same time | 3674F |
| 3674F-S30 | Spectrum analysis function/multichannel spectrum testing | 3674F |
| 3674G-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674G-201 + 3674G-204; 4-port requires options 3674G-401 + 3674G-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately | 3674G |
| 3674G-008 | Pulse measurement; for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674G |
| 3674G-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires options 3674G-400 + 3674G-404 | 3674G |
| 3674G-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674G-400 + 3674G-404 + 3674-S20 | 3674G |
| 3674G-201 | 2-port programmable step attenuator: 2...60 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674G-204 | 3674G |
| 3674G-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674G-204; 3674G-205 cannot be configured at the same time | 3674G |
| 3674G-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674G |
| 3674G-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674G-201 + 3674G-204; 3674G-203 cannot be configured at the same time | 3674G |
| 3674G-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...44 GHz | 3674G |
| 3674G-401 | 4-port programmable step attenuator: 4...60 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674G-400 + 3674G-404 | 3674G |
| 3674G-402 | Active intermodulation distortion measurement; requires options 3674G-400 + 3674G-404 + 3674G-S20 | 3674G |
| 3674G-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674G-400 + 3674G-404; 3674G-405 cannot be configured at the same time | 3674G |
| 3674G-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires options 3674G-400 | 3674G |
| 3674G-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674G-400 + 3674G-401 + 3674G-404; 3674G-403 cannot be configured at the same time | 3674G |
| 3674G-S30 | Spectrum analysis function/multichannel spectrum testing | 3674G |
| 3674H-003 | Noise figure measurement; for accurate measurement of S parameters, noise coefficient, and noise parameters; 2-port requires options 3674H-201 + 3674H-204; 4-port requires options 3674H-401 + 3674H-404; note: 2-port electronic calibrators and ordinary noise sources need to be purchased separately | 3674H |
| 3674H-008 | Pulse measurement; for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674H |
| 3674H-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires options 3674H-400 + 3674H-404 | 3674H |
| 3674H-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674H-400 + 3674H-404 + 3674-S20 | 3674H |
| 3674H-201 | 2-port programmable step attenuator: 2...60 dB step attenuators for source path and 2...35 dB step attenuators for receiver path; requires option 3674H-204 | 3674H |
| 3674H-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires option 3674H-204; 3674H-205 cannot be configured at the same time | 3674H |
| 3674H-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674H |
| 3674H-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674H-201 + 3674H-204; 3674H-203 cannot be configured at the same time | 3674H |
| 3674H-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...50 GHz | 3674H |
| 3674H-401 | 4-port programmable step attenuator: 4...60 dB step attenuators for source path and 4...35 dB step attenuators for receiver path; requires options 3674H-400 + 3674H-404 | 3674H |
| 3674H-402 | Active intermodulation distortion measurement: for active intermodulation distortion signal measurement; requires options 3674H-400 + 3674H-404 + 3674-S20 | 3674H |
| 3674H-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674H-400 + 3674H-404; 3674H-405 cannot be configured at the same time | 3674H |
| 3674H-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674H-400 | 3674H |
| 3674H-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674H-400 + 3674H-401 + 3674H-404; 3674H-403 cannot be configured at the same time | 3674H |
| 3674H-S30 | Spectrum analysis function/multichannel spectrum testing | 3674H |
| 3674K-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674K |
| 3674K-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires option 3674K-400 + 3674K-404 | 3674K |
| 3674K-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674K-400 + 3674K-404 + 3674-S20 | 3674K |
| 3674K-201 | 2-port programmable step attenuator: 2...50 dB step attenuators for source path and 2...50 dB step attenuators for receiver path; requires option 3674K-204 | 3674K |
| 3674K-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674K-204; 3674K-205 cannot be configured at the same time | 3674K |
| 3674K-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674K |
| 3674K-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires option 3674K-201 + 3674K-204; 3674K-203 cannot be configured at the same time | 3674K |
| 3674K-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...53 GHz | 3674K |
| 3674K-401 | 4-port programmable step attenuator: 4...50 dB step attenuators for source path and 4...50 dB step attenuators for receiver path; requires option 3674K-400 + 3674K-404 | 3674K |
| 3674K-402 | Active intermodulation distortion measurement; for active intermodulation distortion signal measurement; requires options 3674K-400 + 3674K-404 + 3674-S20 | 3674K |
| 3674K-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674K-400 + 3674K-404; 3674K-405 cannot be configured at the same time | 3674K |
| 3674K-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674K-400 | 3674K |
| 3674K-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires options 3674K-400 + 3674K-401 + 3674K-404; 3674H-403 cannot be configured at the same time | 3674K |
| 3674K-S30 | Spectrum analysis function/multichannel spectrum testing | 3674K |
| 3674L-008 | Pulse measurement for the S parameter measurement in the pulse state, ports 1 and 3 output the pulse modulation signal | 3674L |
| 3674L-018 | Multi-port expansion device; for the extended vector network analyzer is 16 ports; requires options 3674L-400 + 3674L-404 | 3674L |
| 3674L-023 | Mixer/converter vector measurement; for the mixer-based vector parameter measurement; requires options 3674L-400 + 3674KL-404 + 3674-S20 | 3674L |
| 3674L-201 | 2-port programmable step attenuator: 2...50 dB step attenuators for source path and 2...50 dB step attenuators for receiver path; requires option 3674L-204 | 3674L |
| 3674L-203 | 2-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674L-204; 3674L-205 cannot be configured at the same time | 3674L |
| 3674L-204 | Configurable test set; expand the test device of the 2-port model, add the panel jumper, and can use A, B, R1, R2 receiver independently | 3674L |
| 3674L-205 | 2-port T-type bias-tees; two T-type biasing devices are configured internally for the port output DC offset voltage; requires option 3674L-201 + 3674L-204; 3674L-203 cannot be configured at the same time | 3674L |
| 3674L-400 | 4-port measurement dual-source excitation 4-port vector network analyzer configuration with a frequency range of 10 MHz...67 GHz | 3674L |
| 3674L-401 | 4-port programmable step attenuator: 4...50 dB step attenuators for source path and 4...50 dB step attenuators for receiver path; requires options 3674L-400 + 3674L-404 | 3674L |
| 3674L-402 | Active intermodulation distortion measurement; for active intermodulation distortion signal measurement; requires options 3674L-400 + 3674L-404 + 3674-S20 | 3674L |
| 3674L-403 | 4-port 500 Hz low-frequency expansion; the lower frequency range can be extended to 500 Hz; requires options 3674L-400 + 3674L-404; 3674L-405 cannot be configured at the same time | 3674L |
| 3674L-404 | Configurable test set; expand the test device of the 4-port model, add the panel jumper, and can independently use A, B, C, D, R1, R2, R3, R4 receivers; requires option 3674L-400 | 3674L |
| 3674L-405 | 4-port T type bias-tees; four T-type biasing devices are configured internally for the port output DC offset voltage; requires option 3674L-400 + 3674L-401 + 3674L-404; 3674L-403 cannot be configured at the same time | 3674L |
| 3674L-S30 | Spectrum analysis function/multichannel spectrum testing | 3674L |
| 3674N-400 | 4-port measurement option; dual source excitation 4-port vector network analyzer configuration with frequency range 10 MHz...90 GHz | 3674N |
| 3674x-JL | Metrological calibration services and reports; on request | All models |
| 3674x-EWT1 | Extended warranty for 1 year; on request | All models |
| Calibration options | Calibration kits etc. available, see accessories tab | All versions |