Benefits of the Ceyear 4052A/B/C/D/E/F/G/H Series Signal/Spectrum Analyzers

  • Frequency ranges from 2 Hz up to 4, 9, 13.2, 18, 26.5, 40, 45, or 50 GHz.
  • Excellent test dynamic range, phase noise, amplitude accuracy and fast test speed.
  • 1.2 GHz analysis bandwidth - 6 options from 10 MHz (standard) to 1.2 GHz.

Ceyear4052 Series Mid-Range Spectrum Analyzers up to 50 GHz

The mid-range spectrum analyzers from the Ceyear 4052 series offer excellent test dynamic range, phase noise, amplitude accuracy and measurement speed. They have rich test functions such as spectrum analysis, I/Q analysis, real-time spectrum analysis, transient analysis, vector signal analysis, pulse analysis, and audio analysis functions. With tis they are the ideal solution for testing in wireless communications, automotive electronics, low-orbit satellites, Internet of Things, aerospace and defense and other fields.

  • Mid-range spectrum analyzers with first-class spectrum performance and characteristics.
  • Frequency ranges from 2 Hz up to 4, 9, 13.2, 18, 26.5, 40, 45, or 50 GHz.
  • Coaxial frequency coverage: 2 Hz to 50 GHz.
  • Maximum 1.2 GHz analysis bandwidth (optional bandwidth from 10 MHz to 1.2 GHz.
  • Excellent phase noise performance: -122 dBc/Hz at 1 GHz carrier at 10 kHz offset.
  • 10 Gigabit network interface.
  • Full bandwidth of real-time recording and playback.
  • Powerful mobile communication, satellite signal analysis function.
  • 11.6"/29.5 cm high-resolution multi-touch display.

Model Overview

Model4052A4052B4052C4052D4052E4052F4052G4052H
Frequency rangeDC coupled2 Hz...4 GHz2 Hz...9 GHz2 Hz...13.2 GHz2 Hz...18 GHz2 Hz...26.5 GHz2 Hz...40 GHz2 Hz...45 GHz2 Hz...50 GHz
AC coupled10 MHz...4 GHz10 MHz...8 GHz10 MHz...13.6 GHz10 MHz...18 GHz10 MHz...26.5 GHz10 MHz...40 GHz10 MHz...45 GHz10 MHz...50 GHz
Resolution bandwidthRange: 0.1 Hz...20 MHz (1-2-3-5-steps); conversion uncertainty: ±0.10 dB (1 Hz...1 MHz, 1-2-3-5-steps); ±0.30 dB (5 MHz...20 MHz, 1-2-3-5-steps
Analysis bandwidthStandard: 10 MHz;
option H38-40: 40 MHz;
option H38-200: 200 MHz;
option H38-400: 400 MHz;
option H38-600: 600 MHz;
option H38-1200: 1.2 GHz
Video bandwidth1 Hz...20 MHz (1-2-3-5-steps)
DANL-154 dBm/Hz at 1 GHz, can reach -165 dBm/Hz after configuring the pre-amplifier, and -172 dBm/Hz after the noise cancellation function is turned on (more detailed - see datasheet)
SBB phase noise-122 dBc/Hz at 1 GHz carrier at 10 kHz offset (more detailed - see datasheet)
TOI10 MHz ≤ f ≤ 200 MHz typ. +17 dBm,
200 MHz < f ≤ 4 GHz typ. +19 dBm,
4 GHz < f ≤ 8 GHz typ. +20 dBm,
8 GHz < f ≤ 50 GHz typ. +18 dBm
SweepSweep time range frequency span ≥10 Hz: 1 ms to 16000 s; frequency span 0 Hz: 1 µs to 16000 s
Display11.6"/29.5 cm high-resolution multi-touch display
InterfacesUSB 2.0, USB 3.0, LAN/Ethernet, GPIB
Dimensions (WxHxD, mm)475 x 193 x 560 or 426 x 177 x 450 (with/without handle, foot-pad, bottom feed); depending on version/options approx. 25 kg

Ceyear 4052 Series Options and Accessories

tr>
ModelDescription
4052-H02Auxiliary high IF output: output second IF signal, frequency 425 MHz, 750 MHz
4052-H08Wideband log detection signal output: output a logarithmic detection signal reflecting the level characteristics of the input signal
4052-H1110 Gigabit Ethernet control and data interface, fibre-based, for fast remote control and fast IQ data transfer; requires option 4052-H17-E.
4052-H12CWideband digital interface (WDI): output broadband IQ acquisition data in real time via optical fibre, and supports IQ data output with a maximum bandwidth of 400 MHz. Together with the large-capacity data logger (4712C data logger), real-time large-capacity recording of IQ data can be realised (note: 4052-H12C is optional when the analysis bandwidth is ≤400 MHz)
4052-H12EWideband digital interface (WDI): output via optical fibre in real time, supporting IQ data output with a max. bandwidth of 1.2 GHz. Together with the large-capacity data logger (4712E data logger), real-timelarge-capacity recording of IQ data can be realised (note: 4052-H12E is optional when 600 MHz ≤ analysis bandwidth ≤1.2 GHz)
4052-H22C-4T4712C data loggerInterconnected with a signal/spectrum analyser equipped with the 4052-H12C wideband digital interface, real-time high-capacity recording of signal data with a max. analysis bandwidth of 400 MHz can be achieved, and detailed specifications and parameters of the recorder are shown in the 4712 series data logger information
4052-H22C-8T4712C data logger
4052-H22C-16T4712C data logger
4052-H22C-32T4712C data logger
4052-H22E-8T4712E data loggerInterconnected with a signal/spectrum analyser equipped with the 4052-H12E wideband digital interface, real-time high-capacity recording of signal data up to a max. analysis bandwidth of 1.2 GHz can be achieved, the detailed specifications of the recorder parameters see the 4712 series data logger information
4052-H22E-16T4712E data logger
4052-H22E-32T4712E data logger
4052-H22E-64T4712E data logger
4052-H17-EEnhanced processor (CPU), update to I7 series processor
4052-H19-2TLocal memory expansion, supports up to 2 TB storage memory (electronic hard disk)
4052-H19-4TLocal memory expansion, supports up to 4T B storage memory (electronic hard disk)
4052-H33-08Electronic attenuator, frequency range: 9 kHz...8 GHz, attenuation range: 30 dB, in 0.5-dB steps
4052-H34-04Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052A frequency upper limit is 4 GHz, pre-amplifier select option H34-04
4052-H34-08Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052B frequency upper limit is 8 GHz, pre-amplifier select option H34-08
4052-H34-13Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052C frequency upper limit is 13.6 GHz, pre-amplifier select option H34-13
4052-H34-18Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052D frequency upper limit is 18 GHz, pre-amplifier select option H34-18
4052-H34-26Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052E frequency upper limit is 26.5 GHz, pre-amplifier select option H34-26
4052-H34-40Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052F frequency upper limit is 40 GHz, pre-amplifier select option H34-40
4052-H34-45Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052G frequency upper limit is 45 GHz, pre-amplifier select option H34-45
4052-H34-50Low-noise pre-amplifier, selected according to the frequency upper limit of the signal analyzer; example: 4052H frequency upper limit is 50 GHz, pre-amplifier select option H34-50
4052-H34A-04Low-noise pre-amplifier - only 4052A mainframe can be configured, and 4052-H34-04 is not optional at the same time
4052-H34A-08Low-noise pre-amplifier - only 4052B mainframe can be configured, and 4052-H34-08 is not optional at the same time
4052-H36Pre-selector bypass - tracking pre-selector in the bypass receiving channel
4052-H38-4040 MHz analysis bandwidth, 10 Hz...40 MHz
4052-H38-200200 MHz analysis bandwidth, 10 Hz...200 MHz
4052-H38-400400 MHz analysis bandwidth, 10 Hz...400 MHz
4052-H38-600600 MHz analysis bandwidth, 10 Hz...600 MHz
4052-H38-12001. 2GHz analysis bandwidth, 10 Hz...1.2 GHz
4052-H39Audio analyzer: audio signal parameters test, distortion test and waveform analysis
4052-H40External frequency extender, extends the frequency range using external frequency mixing method. This option provides LO output and IF input, as well as signal recognition ability. (Notes: this option can be selected when the main unit is not 4052A and 4052B: the extended frequency range depends on the selected extension modules; the frequency extension module needs to buy additionally)
4052-H41-10Real-time spectrum analysis, provides digital phosphor spectrum and seamless waterfall, including frequency template trigger, which can support real-time spectrum analysis of 10 MHz bandwidth
4052-H41-40Real-time spectrum analysis, provides up to 40 MHz bandwidth digital fluorescence spectrum and seamless waterfall plot functionality, including frequency template triggering, broadband real-time spectrum analysis (requires the option H38 as well; this option is available when configuring, H38-40, H38-200, H38-400, H38-600, H38-1200)
4052-H41-200Real-time spectrum analysis, provides up to 40 MHz bandwidth digital fluorescence spectrum and seamless waterfall plot functionality, including frequency template triggering, broadband real-time spectrum analysis (requires the option H38 as well; this option is available when configuring, H38-200, H38-400, H38-600, H38-1200)
4052-H41-400Real-time spectrum analysis, provides up to 40 MHz bandwidth digital fluorescence spectrum and seamless waterfall plot functionality, including frequency template triggering, broadband real-time spectrum analysis (requires the option H38 as well; this option is available when configuring, H38-400, H38-600, H38-1200)
4052-H48Noise figure analysis, provide noise source drive and noise figure measurement function. 4052N/P only support maximum 67 GHz noise figure measurement (note: the option needs to select low-noise pre-amplifier option and corresponding 1660X noise source to finish the noise figure measurement. This option and H39 audio analysis cannot be selected simultaneously)
4052-H96Printed user manual, English
4052-H97Mounting rack handles and accessories for 4052 mounting on standard racks
4052-H98English option: English panel, English manual, English operation interface and English operating system
4052-H99-1High-strength lightweight aluminum transportation case, with handle and roller, convenient for transportation
4052-H99-2High strength plastic safety tie rod with wheel packing box, with handle and roller, easy to transport
4052-S01Absolute power measurement: the RF signal power is measured with high precision by means of an external USB power sensor (the corresponding 8723X series power sensor is required)
4052-S02Noise power ratio measurement
4052-S04Phase noise measurement: SSB phase noise curves and single-point phase noise measurement
4052-S05EMC pre-compliance measurement function
4052-S09Analog demodulation option: the modulation characteristics and distortion characteristics of AM, FM and FM signals are analyzed
4052-S10Transient analyzer: measurement and analysis of transient parameters, spectrum, and time-varying characteristics of signals, support playback of the recorded data
4052-S10HFrequency hopping signal analysis: automatic measurement of frequency hopping signal residence time, switching time, frequency and error characteristics (S10 option required)
4052-S10FFMCW signal analysis: automatic measurement of FMCW signal slope, deviation, power and other characteristics (S10 option required)
4052-S12Vector signal analyzer: flexible demodulation functions of multiple single-carrier digital modulation signals. It can provide vector charts, constellation diagrams, eye diagrams, spectrum diagrams, etc., to analyze the characteristics of the modulation signal. The modulation error of the signal can be obtained by demodulation, which helps to judge the cause of the signal error
4052-S12BBER test function: BER test based on known data imported from files, known data recorded by users, PRBS; provide BER result output (need to match S12 option at the same time)
4052-S12MMulti-modulation analysis function: demodulation analysis of signals complying with DVB-S2/X standards; provide display windows for constellation diagrams, symbol tables, etc.; provide modulation quality analysis results such as EVM and origin offset (S12 option is required at the same time)
4052-S13Pulse signal analyzer: automatic measurement on time, level and modulation parameters of pulse waveform and statistical analysis of pulse sequence
4052-S14OFDM signal analysis function: custom OFDM signal modulation analysis; supports multi-parameter custom configurations such as lead, lead-frequency, CP, subcarrier, number of symbols, etc.; has view windows such as capture storage, power spectral density, constellation diagram, and result summary table
4052-S16Multicarrier group delay measurement: absolute and relative group delay measurement capability for wideband signals
4052-S40WLAN 802.11a/b/g measurement: broadband wireless local area network protocol physical layer test (802.11a/b/g), covering radio frequency, modulation analysis, and modulation quality testing
4052-S40NWLAN 802.11n measurement: broadband wireless local area network protocol physical layer test (802.11n), covering radio frequency, modulation analysis, and modulation quality testing
4052-S40ACWLAN 802.11ac measurement: broadband wireless local area network protocol physical layer test (802.11ac), covering radio frequency, modulation analysis, and modulation quality testing
4052-S40AXWLAN 802.11ax measurement: broadband wireless local area network protocol physical layer test (802.11ax), covering radio frequency, modulation analysis, and modulation quality testing
4052-S40BEWLAN 802.11be signal analysis: broadband WLAN protocol physical layer testing (802.11be), covering RF, modulation analysis, modulation quality testing (requires concurrent S40 option)
4052-S41DLTE/LTE-A TDD downlink signal modulation analysis; support TDD each subframe configuration type modulation analysis; support custom parameter configuration modulation analysis; support downlink E-TM template modulation analysis; support EVM, switching power, frequency error, power and other parameter measurements; provide view outputs such as capture storage, power spectral density, constellation diagram, result summary table, EVM vs. carrier and so on
4052-S41ULTE/LTE-A TDD uplink signal modulation analysis; support custom parameter configuration modulation analysis; support EVM, frequency error, power and other parameter measurements; provide view outputs such as capturestorage, power spectral density, constellation diagram, result summary table, EVM vs. carrier, and so on
4052-S42DLTE/LTE-A FDD downlink signal modulation analysis; support custom parameter configuration modulation analysis; support downlink E-TM template modulation analysis; support EVM, frequency error, power and other parameter measurements; provide view outputs such as Capture Storage, Power Spectral Density, Constellation Diagram, Result Summary Table, EVM vs. Carrier, and so on
4052-S42ULTE/LTE-A FDD uplink signal modulation analysis; support custom parameter configuration modulation analysis; support EVM, frequency error, power and other parameter measurements; provide view outputs such as capture storage, power spectral density, constellation diagram, result summary table, EVM vs. carrier, and so on
4052-S46D5G NR downlink signal demodulation, EVM, spectrum flatness, time alignment error; support ACP, spectrum emission template, transmit on/off, CCDF and other power measurement; support multiple bandwidth and multiple TM
4052-S46U5G NR uplink signal demodulation, EVM, spectrum flatness, time alignment error; support ACP, spectrum emission template, transmit on/off, CCDF and other power measurement; support multiple bandwidth and multiple TM