ET System EAC-SP Series AC Sources, 1-Phase, 250 to 12,000VA

ETSYSTEM EAC-SP Series AC Sources, 1-phase, 250 to 12,000 VA
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the EAC-SP Linear 1-phase AC Power Supplies up to 12,000 VA

  • 1-phase electronic AC-Sources.
  • AC/DC and AC+DC operation.
  • 250 VA bis 12.000 VA.

ET System EAC-SP Series AC Sources, 1-Phase, 250 to 12,000 VA

When simulating AC networks, the AC sources of ET System are essential. They supply freely adjustable single-phase sine, rectangle or triangle voltages. The manually adjustable frequency range lies between 0...2000 Hz. In addition, often needed frequencies such as 50 Hz, 60 Hz, and 400 Hz can be selected at the press of a button. The entire series has excellent control data, offers a distortion of only 0.1% and DC voltage programming accuracy of 100 mV - all that at a very high control precision of 0.1%.

  • 1-phase electronic AC-Sources.
  • AC/DC and AC+DC operation.
  • 250 VA bis 12.000 VA.
  • 0...700 VAC/1,000 VDC output voltages per phase.
  • Maximum currents up to 600 A per phase.
  • Variable frequencies ranging from 1 to 2000 Hz (sine, square, triangle).
  • Simulation of single- and three-phase networks.
  • Graphic display.
  • Measurement of: Voltage, effective current, average and peak current, effective power, idle power, apparent power, power factor, crest factor.
  • Constant voltage and constant current operating modes (CV, CC).
  • 10 memory spaces to store current configurations.
  • External oscillator input ±10 V with adjustable time delay of up to 70 ms.
  • Free memory spaces for user-programmable curves (WAV files), enabled via an external SD memory card or interface.
  • Script control: Process programming and booting from memory card.
  • Datalog function: Current operation values can be saved to a memory card at adjustable time intervals.
  • Script operation, in combination with the Datalog function, enables an independent stand-alone test field to be set up.
  • Digital interfaces (option): GPIB/IEEE488, RS232, RS485, USB, LAN; LabView driver.
  • Galvanically isolated 0...5 V or 0...10 V analogue interface (optional).
  • SD card slot (optional).
  • Sync input synchronizes the device with external sources (optional).
  • Sync output triggers external measurement instruments or similar (optional).
  • Disengageable output voltage via memory card or digital interface for a determined amount of half periods (optional).
  • Connectable output voltage via memory card or digital interface for a determined amount of time (optional).
  • Special versions available on request.

Our shop gives you a choice of frequently requested standard models.
Various special versions are possible - just call us or send an E-Mail!

Model Overview - Examples

ModelPowerVoltageCurrentDimensions
EAC-SP 250
250 VA
0...300 VAC/0...425 VDC
0...3 A
19" x 3 U x 620 mm
EAC-SP 500
500 VA
0...300 VAC/0...425 VDC
0...6 A
19" x 3 U x 620 mm
EAC-SP 1500
1,500 VA
0...300 VAC/0...425 VDC
0...10 A
19" x 3 U x 620 mm
EAC-SP 2000
2,000 VA
0...300 VAC/0...425 VDC
0...16 A
19" x 6 U x 620 mm
EAC-SP 3000
3,000 VA
0...300 VAC/0...425 VDC
0...20 A
19" x 6 U x 620 mm
EAC-SP 4500
4,500 VA
0...300 VAC/0...425 VDC
0...30 A
19" x 9 U x 620 mm
EAC-SP 5000
5,000 VA
0...300 VAC/0...425 VDC
0...35 A
19" x 9 U x 620 mm
EAC-SP 6000
6,000 VA
0...300 VAC/0...425 VDC
0...40 A
19" x 9 U x 620 mm
EAC-SP 7500
7,500 VA
0...300 VAC/0...425 VDC
0...50 A
19" x 9 U x 620 mm
EAC-SP 8000
8,000 VA
0...300 VAC/0...425 VDC
0...60 A
19" x 12 U x 620 mm
EAC-SP 9000
9,000 VA
0...300 VAC/0...425 VDC
0...70 A
19" x 12 U x 620 mm
EAC-SP 10500
10,500 VA
0...300 VAC/0...425 VDC
0...80 A
19" x 12 U x 620 mm
EAC-SP 12000
12,000 VA
0...300 VAC/0...425 VDC
0...90 A
19" x 18 U x 620 mm

Options

OptionDescription
...-230Input 230/207...253 VAC
...-400Input 400/360...440 VAC
...-3P208Input 3x 208/187...229 VAC
...-3P400Input 3x 400/360...440 VAC
...-3P480Input 3x 480/432...528 VAC
...-V500Extended voltage range 0...500 VAC/0...700 VDC -40% Imax
...-V700Extended voltage range 0...700 VAC/0 ...1,000 VDC -50% Imax
...-F1000Extended frequency range 1...1,000 Hz
...-F2000Extended frequency range 1...2,000 Hz
...-LTGPIBInterface GPIB/IEEE488
...-LTRS485 Interface RS485
...-LTRS232Interface RS232
...-LANInterface LAN
...-USBInterface USB
...-ATI5Galvanically isolated analog interface 0...5 VDC
...-ATI10Galvanically isolated analog interface 0...10 VDC
...-EXT-OSZExternal oscillator input
...-SDSD card slot
...-SYNCASync output for triggering external measurement devices or similar
...-SYNCESync input for synchronization with external sources
..-INTLOCKInterlock input/safety shutdown
...-DIPDisengageable output voltage during a specific number of half periods (digital interface required)
...-GATEEngageable output voltage during a specific amount of time (digital interface required)
...-APulsAdjustable puls sequence (digital interface required)
...-LoadRLoad reverse energy recovery
...-LoadLRLoad energy recovery/regeneration in development