Microedge Product Line
Rugged, Autonomous Dataloggers
- Compact dataloggers for current, voltage, temperature, humidity.
- Autonomous with longtime battery operation. Deep memory.
- USB port for data communication.
€
644,98
€
644,98
€
777,07
€
909,16
Microedge Product Comparison Table
Voltage Loggers, USB
Model | Channels: 1 channel thermistor on-board (-40...+70°C) and... | Range |
Site-Log LPV-1 | 7-channel programmable voltage | 0...20 V, 0...5 V |
Site-Log LPVB-1* | 7-channel programmable voltage, high accuracy | 0...20 V, -5...+5 V |
Site-Log LFV-1 | 7-channel 20 VDC | 20 VDC |
Site-Log LFV-2 | 7-channel 10 VDC | 10 VDC |
Site-Log LFV-3 | 7-channel 5 VDC | 5 VDC |
Site-Log LFV-4 | 7-channel 2,5 VDC | 2 VDC |
Site-Log LFV-5 | 7-channel 20, 10, 5, 2,5 VDC | Channel 1/20 VDC, channel 2/10 VDC, channel 3/10 VDC, channel 4/5 VDC, channel 5/5 VDC, channel 6/2 VDC, channel 7/2 VDC |
Site-Log LFVB-1* | 7-channel 20 VDC, high accuracy | 20 VDC |
Site-Log LFVB-2* | 7-channel 10 VDC, high accuracy | 10 VDC |
Site-Log LFVB-3* | 7-channel 5 VDC, high accuracy | 5 VDC |
Site-Log LFVB-4* | 7-channel 2,5 VDC, high accuracy | 2 VDC |
Site-Log LFVB-5* | 7-channel 20, 10, 5, 2,5 VDC, high accuracy | Channel 1/20 VDC, channel 2/10 VDC, channel 3/10 VDC, channel 4/5 VDC, channel 5/5 VDC, channel 6/2 VDC, channel 7/0,6 VDC |
Site-Log LPM-1 | 7-channel programmable voltage/current DC | Channel 1...4: 0...20 V, 0...5 V channel 5...7: 4...20 mA, 0...50 mA |
Site-Log LPMB-1* | 7-channel programmable voltage/current DC, high accuracy | Channel 1...4: 0...20 V, -5 ...+5 V channel 5...7: 4...20 mA, 0...50 mA |
Site-Log LFM-1 | 7-channel voltage/current DC | Channel 1/20 VDC, channel 2/10 VDC, channel 3/5 VDC, channel 4/2 VDC, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA (12 Ω load resistor for the current channels) |
Site-Log LFMB-1* | 7-channel voltage/current DC, high accuracy | Channel 1/20 VDC, channel 2/10 VDC, channel 3/5 VDC, channel 4/2 VDC, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA (12 Ω load resistor for the current channels) |
iLog iVDC-10 | 1 channel voltage | 10 VDC |
* Models "B" with high accuracy.
Current Loggers, USB
Model | Channels: 1 channel thermistor on-board (-40...+70°C) and... | Range |
Site-Log LPC-1 | 7-channel programmabler current DC | 4...20 mA, 0...50 mA (12 Ω load resistor) |
Site-Log LPCB-1* | 7-channel programmabler current DC, high accuracy | 4...20 mA, 0...50 mA (12 Ω load resistor) |
Site-Log LFC-1 | 7-channel 4...20 mA | 4...20 mA (12 Ω load resistor) |
Site-Log LFC-2 | 7-channel 50 mA | 50 mA (12 Ohm load resistor) |
Site-Log LFC-3 | 7-channel 50, 25, 20, 4...20, 12, 6 mA | Channel 1/50 mA, channel 2/50 mA, channel 3/50 mA, channel 4/4...20 mA, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA |
Site-Log LFCB-1* | 7-channel 4...20 mA, high accuracy | current: 4...20 mA (12 Ω load resistor) |
Site-Log LFCB-2* | 7-channel 50 mA, high accuracy | current: 50 mA (12 Ω load resistor) |
Site-Log LFCB-3* | 7-channel 50, 25, 20, 4...20, 12, 6 mA, high accuracy | current: channel 1/50 mA, channel 2/50 mA, channel 3/50 mA, channel 4/4...20 mA, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA |
Site-Log LPM-1 | 7-channel programmable voltage/current DC | Channel 1...4: 0...20 V, 0...10 V, 0...5 V, 0...2 V, channel 5...7: 4...20 mA, 0...50 mA |
Site-Log LPMB-1* | 7-channel programmable voltage/current DC, high accuracy | Channel 1...4: 0...20 V, 0...10 V, 0...5 V, 0...2 V, -5 ...+5 V, -2...+2 V, channel 5...7: 4...20 mA, 0...50 mA |
Site-Log LFM-1 | 7-channel voltage/current DC | Channel 1/20 VDC, channel 2/10 VDC, channel 3/5 VDC, channel 4/2 VDC, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA (12 Ω load resistor für die current-Kanäle) |
Site-Log LFMB-1* | 7-channel voltage/current DC, high accuracy | Channel 1/20 VDC, channel 2/10 VDC, channel 3/5 VDC, channel 4/2 VDC, channel 5/4...20 mA, channel 6/4...20 mA, channel 7/4...20 mA (12 Ω load resistor für die current-Kanäle) |
iLog iCDC-25 | 1 channel current | 25 mA |
* Models "B" with high accuracy.
Temperature Loggers, Relative Humidity, USB
Model | Channels: 1 channel thermistor on-board (-40...+70°C) and... | Range |
Site-Log LPTM-1 | 7-channel programmable thermocouple inputs | -8...+73 mV, -2...+18 mV |
Site-Log LRHT-1 | 1-channel relative humidity, internal Sensor | 0...100% |
Site-Log LRHT-2 | 1-channel relative humidity, external Sensor | 0...100% |
Site-Log LPTH-1 | 7-channel thermistor | 16 bit (1/65535) |
Site-Log LRTD-x | 1 channel internal thermistor, 4 channels RTDs, depending on version PT100, PT500, PT1000 | 16 bit |
iLog iTC-80 | 1 channel for thermocouples (B, E, J, K, N, R, S, T) | -8...+73 mV |
iLog iTH-10 | 1 channel for thermistor |
WiFi Dataloggers
Model | Channels | Ranges |
precise-Log-VW | 8-channel, programmable ranges, DC voltage | 0...20 V, 0...5 V |
precise-Log-CW | 8-channel, programmable ranges, DC-current | 0...20 mA, 0...50 mA |
precise-Log-HW | 8-channel external thermistors | |
precise-Log-TW | 8-channel external thermocouples J, K, T, E, R, S, B, N |