SEFRAM7200 Series Handheld Digital Multimeters
starting €
46,41
including VAT
plus shipping
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads
Benefits of the SEFRAM7200 TRMS Industrial Multimeters
- Robust handheld digital multimeters for technicians, electricians, and installers.
- Model 7212 autorange fpr heating engineers, maintenance services, etc.
- TRMS (True RMS) AC voltage, DC voltage up to 600 or 1000 V.
SEFRAM7200 Series Handheld Digital Multimeters
SEFRAM7208, SEFRAM7212, SEFRAM7214 Professional DMM-Performance in your Pocket
The SEFRAM7200 series handheld digital multimeters offer basic measurement features for general applications or advanced features, designed to meet the needs of electricians, heating engineers, and maintenance services. The devices are compact in size and robust for reliable use in the field.
- DC voltage measurement up to 600 VDC, model SEFRAM7214 up to 1000 VDC.
- TRMS (True RMS) AC voltage measurement up to 600 VAC, model SEFRAM7214 up to 750 VAC.
- SEFRAM7212 and 7214: DC and AC currents from µA to 10 A (ideal for heating and maintenance).
- Non-contact voltage detection (NCV).
- Measurements of resistance, diodes, continuity.
- Advanced measurements models SEFRAM7212, 7214: frequency, capacitance, SEFRAM 7214: temperature (type K thermocoule).
- SEFRAM7212: VFD filter for variable speed drives and disturbed signals; MIN/MAX, REL, HOLD functions.
- CAT III 600 V safety ratings, model SEFRAM7214 CAT IV 600 V/CAT III 1000 V.
- 3 measurements per second.
- Backlit LCD display.
Model Overview
| Model | SEFRAM7208 | SEFRAM7212 | SEFRAM7214 | |
| Measurements | DC voltage | Range 200 mV...600 V (5 ranges); resolution 0.1 mV...1 V; basic accuracy ±(0.8% of reading + 5 digits) | Range 60 mV...600 V (5 ranges); resolution 10 µV...100 mV; basic accuracy ±(0,5% + 3 digits) | Range 600 mV...1000 V (5 ranges); resolution 0.1 mV...1 V; basic accuracy ±(0.5 % of reading + 3 digits) |
| AC voltage | TRMS (True RMS) range 2...600 V (4 ranges); resolution 0.001...1 V; basic accuracy ±(1.2 % of reading + 5 digits); frequency 40...1000 Hz | TRMS (True RMS) range 60 mV...600 V (5 ranges); resolution 10 µV...100 mV; basic accuracy ±(0,8% + 3 digits); bandwidth 40 Hz...1 kHz | TRMS (True RMS) range 6...750 V (4 ranges); resolution 1 mV...1 V; basic accuracy ±(0.8% of reading + 3 digits); frequency 40...1000 Hz | |
| DC current | - | Range 600 µA...10 A (6 ranges); resolution 0,1 µA...10 mA: basic accuracy ±(0,8% + 3 digits) | Range 60 µA...10 A (6 ranges); resolution 0.01 µA...10 mA; basic accuracy ±(0.8% of reading + 3 digits) | |
| AC current | - | TRMS (True RMS); range 600 µA...10 A (6 ranges); resolution 0,1 µA...10 mA; basic accuracy ±(1% + 5 digits); bandwidth 40 Hz...1 kHz | TRMS (True RMS) range 60 µA...10 A (6 ranges); resolution 0.01 µA...10 mA; basic accuracy ±(1% of reading + 3 digits) | |
| Frequency | - | Range 10 Hz...10 MHz (7 ranges); basic accuracy ±(1% + 5 digits) | Range 9.999 Hz...9.999 MHz (7 ranges); resolution 0.001 Hz...0.001 MHz; basic accuracy ±(1% of reading + 3 digits) | |
| Capacitance | - | Range 10 nF...100 mF; resolution 0,01 nF...0,1 mF; basic accuracy ±(3% + 5 digit) | Range 6 nF...0.01 mF (8 ranges); resolution 0.001 nF...0.1 mF; basic accuracy ±(4% of reading + 3 digits) | |
| Resistance | Range 200 Ω...20 MΩ (6 ranges); resolution 0.1 Ω...10 kΩ; basic accuracy ±(0.8 % + 3 digits) | Range 600 Ω...60 MΩ (6 ranges); basic accuracy ±(1,2% + 5 digits) | Range 600 Ω...60 MΩ (6 ranges); resolution 0.1 Ω...10 kΩ; basic accuracy ±(0.8% of the reading + 3 digits) | |
| Diode | ✓; range 2 V; resolution 0.001 V; open circuit voltage 2.4 V; the display shows the value of the forward voltage drop of the diode | ✓ | ✓; range 0...3 V; resolution 0.001 V; open circuit voltage approx. 3.2 V; direct current approx. 1 mA; the display indicates the approximate value of the forward voltage drop across the diode | |
| Continuity | Emits an audible signal when the measured resistance value is less than 35 Ω; test current approx. 1 mA; open circuit voltage 2.4 V | ✓ with buzzer (30 Ω) | Emits an audible signal when the measured resistance value is less than 35 Ω; test current approx. 1 mA; open circuit voltage 2.4 V, measurement range 600 Ω resolution 0.1 Ω | |
| Temperature | - | - | Thermocouple type K; range -20...+1000°C; resolution 1°C; basic accuracy ±(1% of reading + 3 digits) | |
| Measurement rate | 3 measurements/s | 3 measurements/s | 3 measurements/s | |
| Display | LCD, backlit; 6000 counts | LCD, backlit; 6000 counts with bargraph | LCD, backlit; 6000 counts with bargraph | |
| Security | CAT III 600 V | CAT III 600 V | CAT IV 600 V/CAT III 1000 V | |
| Power supply | 2 AAA batteries 1.5 V | 2 AAA batteries 1.5 V | 4 AA batteries 1.5 V | |
| Dimensions (mm) | 128 x 61 x 25; 200 g | 166 x 78 x 64; 268 g | 190 x 89 x 50; 380 g | |
| Operating temperature | 0...+40°C | 0...+40°C | 0...+40°C | |
Included: Handheld digital multimeter SEFRAM 7208, 7212, or 7214, test leads, batteries, 7212/7214: carrying case, 7214: temperature probe.
Information on product safety:
Manufacturer:
SEFRAM Instruments SAS, 32, rue E. Martel, F42100 St Etienne/FRA
www.sefram.com