TekBox TBL5000 LISN Series Line Impedance Stabilization Networks
Benefits of the TekBox TBL5000 LISN Series Stabilisation Networks
- For the measurement of line-conducted interferences and noise measurements.
- Series for the frequency range 9 kHz to 30 MHz or 100 MHz.
- The ideal solution for pre-compliance EMC testing according to CISPR16-1-2, etc.
TekBox TBL5000 LISN Series Line Impedance Stabilization Networks
TekBox Models TBL5008-2B, TBL5008-2C, TBL5016-1, TBL5016-2B, TBL5016-2C, TBL5016-3, TBL5032-3 30 MHz LISNs
LISNs to measure conducted emissions on power supply lines in the 9 kHz to 30 MHz (100 MHz) frequency range, as specified by the CISPR 16-1-2 standard.
Model Overview
When ordering, please specify the required country specific socket -EU, -UK, -US, -AU.
(EU, US, AU, UK)
(EU, US, AU, UK)
- Switchable PE 50 Ω||50 µH.
- Independent BNC outputs for line and neutral to provide connectivity for CM/DM separators (LISN Mate).
- Air core inductors.
- Line voltage max. 250 V, 50/60 Hz or DC.
- EUT socket country specific.
- Measurement connector 50 Ω BNC.
- Power connector IEC 60320 C13.
- Operating temperature range +5...+40°C; 5...80% rel. H.
- Switchable PE 50 Ω||50 µH.
- Limiter/ attenuator/ highpass filter: +6 dBm/ 10 dB/ 150 kHz to 30 MHz.
- Air core inductors.
- Line voltage max. 250 V, 50/60 Hz or DC.
- EUT socket country specific.
- Measurement connector 50 Ω BNC.
- Power connector IEC 60320 C13.
- Operating temperature range +5...+40°C; 5...80% rel. H.
- DC resistance <45 mΩ.
- Operating voltage range 0...250 VDC; 0...250 VAC (50/60 Hz), 0...90 VAC (400 Hz).
- Fuse 2x 16 A slow.
- High current plug/screw terminals – male: Phoenix Contact 1998933, female: Phoenix Contact 1967375.
- Dimensions (mm): 250 x 225 x 140 (including ground brackets); 2.7 kg.
- Switchable PE 50 Ω||50 µH.
- Independent BNC outputs for line and neutral to provide connectivity for CM/DM separators (LISN Mate).
- Air core inductors.
- Line voltage max. 250 V, 50/60 Hz or DC.
- EUT socket country specific.
- Measurement connector 50 Ω BNC.
- Power connector IEC 60320 C19.
- Operating temperature range +5...+40°C; 5...80% rel. H.
- Switchable PE 50 Ω||50 µH.
- Limiter/ attenuator/ highpass filter: +6 dBm/ 10 dB/ 150 kHz to 30 MHz.
- Air core inductors.
- Line voltage max. 250 V, 50/60 Hz or DC.
- EUT socket country specific.
- Measurement connector 50 Ω BNC.
- Power connector IEC 60320 C19.
- Operating temperature range +5...+40°C; 5...80% rel. H.
- Switchable PE 50 Ω||50 µH.
- 250 µH pre-filter.
- Separate RF outputs for each line and neutral.
- Air core inductors.
- Line voltage max. 450 V/260 V, 50...60 Hz, CAT II.
- 3-phase DUT socket CEE/IEC60309, 3L+N+PE, 16A, female.
- Single-phase DUT socket country specific.
- Power connector CEE/IEC60309, 3L+N+PE, 16 A, male.
- Measurement connectors 50 Ω BNC.
- Operating temperature range +5...+40°C; 5...80% rel. H.
- Safety Class I, IEC 1010-01.
- Switchable PE 50 Ω||50 µH.
- 250 µH pre-filter.
- Separate RF outputs for each line and neutral.
- Air core inductors.
- Line voltage max. 450 V/260 V, 50...60 Hz, CAT II.
- 3-phase DUT socket CEE/IEC60309, 3L+N+PE, 32A, female.
- Single-phase DUT socket country specific.
- Power connector CEE/IEC60309, 3L+N+PE, 32 A, male.
- Measurement connectors 50 Ω BNC.
- External 9 kHz high pass filter, N-male/N-female.
- Operating temperature range +5...+40°C; 5...80% rel. H.
Note: The model TBL5016-2 is EOL/obsolete and replaced by the versions TBL5016-2B and TBL5016-2C.
Information on product safety:
Manufacturer:
TekBox Digital Solutions Vietnam Co. Ltd., Saigon Hi-Tech Park, Factory 4, 4F, Lot I-3B-1, N6 Street, Thu Duc City, 700 000 Ho Chi Minh City/VNM
www.tekbox.com
Responsible person:
Meilhaus Electronic GmbH, Am Sonnenlicht 2, 82239 Alling/DEU
info@meilhaus.com