Description
Files/Downloads

Benefits of the TBMDA-BCI100 for Conducted Immunity Testing Using BCI Probes per ISO 11452-4

  • CW amplifier (modulation off).
  • 1 kHz, 80% AM modulation, 1 kHz/50% and 217 Hz/12.5% duty cycle pulse modulation.
  • VSWR monitoring.

Tekbox TBMDA-BCI100 Modulated Wideband Power Amplifier

The Tekbox TBMDA-BCI100 modulated amplifier provides the necessary bandwidth and modulation for conducted immunity testing using BCI probes per ISO 11452-4 in the frequency range from 1 MHz to 400 MHz. It is designed to be driven by signal generators or by tracking generators of spectrum analyzers. With a 1 dB compression point of up to 110 W in the frequency range 1 MHz to 400 MHz it can generate test levels up to Level IV with AM and Level IV with CW. A built in AM/PM–modulator enables use of tracking generators as signal source. The TBMDA-BCI100 has sufficient gain to achieve maximum output power with 0 dBm provided by a spectrum analyzer tracking generator.
Besides 1 kHz, 80% AM, the TBMDA-BCI100 provides built in modulation capability to generate 1 kHz, 50% duty cycle PM signals. In PM mode, the TBMDA-BCI100 can also generate a 217 Hz Signal with 12.5% duty cycle in order to simulate mobile phone TDMA noise.

  • Modulated wideband power amplifier.
  • For conducted immunity testing using BCI probes per ISO 11452-4 in the frequency range 1...400 MHz.
  • CW amplifier (modulation off).
  • 1 kHz, 80% AM modulation.
    1 kHz, 50% duty cycle pulse modulation.
    217 Hz, 12.5% duty cycle pulse modulation.
  • VSWR monitoring.
  • Application:
    General-purpose wideband RF power amplifier.
    Wideband RF power amplifier for conducted immunity testing driving BCI-probes.
    Wideband RF power amplifier for radiated immunity testing, driving near field probes.
    Wideband RF power amplifier for radiated immunity testing, driving TEM cells.

Model Overview

ModelTBMDA-BCI100
Input/output50 Ω, N female
Frequency range1...400 MHz
Small signal gain52 dB typ.
Gain flatness1...400 MHz/pin = -3 dBm: 1.5 dB typ.
Maximum output power1 MHz/pin = 0 dBm50.7 dBm (117.5 W) typ.
10 MHz/pin = 0 dBm50.7 dBm (117.5 W) typ.
50 MHz/pin = 0 dBm50.8 dBm (120.2 W) typ.
100 MHz/pin = 0 dBm50.7 dBm (117.5 W) typ.
150 MHz/pin = 0 dBm50.8 dBm (120.2 W) typ.
200 MHz/pin = 0 dBm50.5 dBm (112.2 W) typ.
250 MHz/pin = 0 dBm50.5 dBm (112.2 W) typ.
300 MHz/pin = 0 dBm50.6 dBm (114.8 W) typ.
350 MHz/pin = 0 dBm50.6 dBm (114.8 W) typ.
400 MHz/pin = 0 dBm49.5 dBm (89.1 W) typ.
1 dB output compression point1 MHz50.5 dBm typ. (Pin: -1 dBm)
10 MHz50.5 dBm typ. (pin: -1 dBm)
50 MHz50.8 dBm typ. (pin: 0 dBm)
100 MHz50.7 dBm typ. (pin: 0 dBm)
150 MHz50.5 dBm typ. (pin: -1 dBm)
200 MHz49.8 dBm typ. (pin: -2 dBm)
250 MHz49.8 dBm typ. (pin: -2 dBm)
300 MHz49.7 dBm typ. (pin: -2 dBm)
350 MHz49.8 dBm typ. (pin: -2 dBm)
400 MHz48.6 dBm typ. (pin: -4 dBm)
Harmonics2nd harmonic, 100 MHz, Pout = 44.0 dBm<–20.2 dBc typ.
2nd harmonic, 100 MHz, Pout = 50.0 dBm<–16.3 dBc typ.
3rd harmonic, 100 MHz, Pout = 44.0 dBm<–12.2 dBc typ.
3rd harmonic, 100 MHz, Pout = 50 dBm<–11.9 dBc typ.
Total harmonic distortion27.9% at 100 MHzPout = 44.0 dBm typ.
29.7% at 100 MHzPout = 47.0 dBm typ.
31.9% at 100 MHzPout = 50.0 dBm typ.
Third order output intercept point48 dBm at 100 MHz, &Deltaf = 2 MHz, typ.
Internal modulation frequencyAM: 1 kHz ±20%
PM: 1 kHz ±20%, 217 Hz ±20%
Duty cycle, PM: 50% ±10% at 1 kHz; 12.5% ±20% @ 217 Hz
Maximum ratingsMaximum input power +0 dBm;
the output of the TBMDA-BCI100 is quite tolerant to output mismatch, however open or shorted load is not recommended, as it potentially can cause damage to the output transistor. When driving near field probes, current probes or any load of unknown impedance, it is highly recommended to insert a ≥3 dB attenuator at the output of the amplifier in order to protect the output stage
Power supplySupply voltage range 100...120 VAC or 200...240 VAC 50/60 Hz; supply power consumption 350 W at 220 V
Operating temperature range-20...+50°C
Dimensions (mm)485 x 310 x 135, 10.5 kg


Information on product safety:

Manufacturer:
TekBox Digital Solutions Vietnam Co. Ltd., Saigon Hi-Tech Park, Factory 4, 4F, Lot I-3B-1, N6 Street, Thu Duc City, 700 000 Ho Chi Minh City/VNM
www.tekbox.com

Responsible person:
Meilhaus Electronic GmbH, Am Sonnenlicht 2, 82239 Alling/DEU