Model Overview

Model/option codeDescriptionBandwidthOther specs
P95584456-H03High voltage single-ended probeDC...250 MHzAttenuation 100:1, max. voltage 3000 V, length 200 cm
P32584456-H04High voltage single-ended probeDC...100 MHzAttenuation 100:1, max. voltage 1500 V, length 130 cm
P80504456-H05High voltage differential probeDC...50 MHzAttenuation 50:1/500:1, precision ±2%, max. voltage 1300 V (DC+ACpk), supply 9 VDC
P81004456-H06High voltage differential probeDC...100 MHzAttenuation 50:1/500:1, precision ±2%, max. voltage 1300 V (DC+ACpk), supply 9 VDC
AP6224456-H07Current probeDC...100 kHzMeasurement range 50 mA...100 Apk, range 10 mV/A, 100 mV/A, supply 9 V alkaline batteries
AP2024456-H08Current probeDC...25 MHzPrecision ±3%, max. current 20 A (DC+ACpk), range 100 mV/A, supply 9 VDC
P9550A4456-H12Voltage probeDC...500 MHzAttenuation 10:1, impedance 10 MΩ||10 pF ±2 pF, max. level 300 V CATII, support auto recognize function.
P95514456-H13Passive voltage probeDC...500 MHzAttenuation 10:1/1:1, impedance 10 MΩ||10 pF ±2 pF, max. level 300 V CATII, not support auto recognize function
P9350A4456-H14Passive voltage probeDC...350 MHzAttenuation 10:1, impedance 10 MΩ||10 pF ±2 pF, max. level 300 V CATII, support auto recognize function
P9600A4456-H15Passive voltage probeDC...600 MHzAttenuation 10:1, impedance 10 MΩ||10 pF ±2 pF, max. level 300 V CATII, support auto recognize function
LAP5004456-H16Logic probe, 16 channels, 100 kΩ ±2%; max. level ±40 Vpk
P5020 4456-H17High voltage differential probeDC...20 MHzAttenuation 500:1/5000:1, accuracy ±2%, max. level 40 kV ( C+ACpk-pk)
P6100 4456-H18High voltage differential probeDC...100 MHzAttenuation 100:1/1000:1, accuracy ±1%, max. level 14 kVpk-pk
P7100 4456-H19High voltage differential probeDC...100 MHzAttenuation 100:1/1000:1, accuracy ±1%, max. level 7000 Vpk-pk
P42204456-H20High voltage single-ended probeDC...220 MHzAttenuation 1000:1, accuracy ±3%
AP6214456-H21Current probe10 Hz...100 kHzMeasurement range 2000 Apk, range 100 mV/A, 10 mV/A, 1 mV/A
AP622D4456-H22Current probeDC...1.5 MHzMeasurement range 1 mA...40 Apk
AP204A4456-H23Current probeDC...50 MHzAccuracy ±3%, max. current 40 A (DC+ACpk), range 100 mV/A