HIOKI PW336x Series Clamp-on Power Meters/Loggers

starting 1.437,52
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Benefits of the PW3360/PW3365 Portable Clamp-on Loggers for Single- and 3-Phase

  • Support single to three-phase, 4-wire circuit.
  • Measure between 90 V to 520 V or 780 V.
  • Portable, compact device with display and CF Card, USB, LAN.

HIOKI PW336x Series Clamp-on Power Meters/Loggers

Portable Clamp-on Power Logger HIOKI PW3360

The HIOKI PW3360-20 and -21 are portable power loggers used for for energy audits and energy conservation.

  • Clamp-on power logger designed for 50/60 Hz commercial line us.
  • Supports single to three-phase, 4-wire circuits: 3 circuits (1P2W), single circuit (1P3W, 3P3W, 3P4W). Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system).
  • Measure between 90 V to 780 V.
  • Slim, compact design that can be placed anywhere.
  • Store months of data on SD cards.
  • The "quick set" function guides you in making the right connections.
  • Version PW3360-21 for harmonic measurements up to the 40th order.

Portable Clamp-on Logger HIOKI PW3365

Use the HIOKI PW3365 portable clamp-on power logger to eliminate the risk of short-circuits and electrical accidents.

  • Clamp-on power logger designed for 50/60 Hz commercial line us.
  • Measure voltage from the top of the cable with zero risk of short circuit.
  • Supports single to three-phase, 4-wire circuits: 3 circuits (1P2W), single circuit (1P3W, 3P3W, 3P4W).
  • Measure between 90 V to 520 V.
  • Display harmonics up to the 13th order.
  • Slim, compact design that can be placed anywhere.
  • Store months of data on SD cards.
  • The "quick set" function guides you in making the right connections.
  • Non-metallic contact voltage sensor.

Model Overview

ModelPW3360-20 or PW3360-21PW3365-20
Measurement line and number of circuits50/60 Hz, single-phase 2 wires (1/2/3 circuits), single-phase 3 wires (1 circuit), three phases 3 wires (1 circuit), three phases 4 wires (1 circuit), current only: 1 to 3 channels
Measurement itemsVoltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (PW3360 with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand
Pulse input; PW3360-21 only: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th orderUp to 13th order harmonics
Voltage ranges600 VAC (effective measurement range: 90.00...780.00 V)400 VAC (effective measurement range: 90.0...520.0 V)
Current ranges500.00 mA...5.0000 kAAC (depends on current sensor in use),
50.000 mA...5.0000 AAC (leak clamp on sensor only)
Power ranges300.00 W...9.0000 MW (depends on voltage/current combination and measured line type)200.00 W...6.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracyVoltage: ±0.3% rdg. ±0.1% f.s;
current: ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy;
active power: ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Voltage: ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020);
current: ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy;
active power: ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate0.5 s (except when accessing SD card or internal memory, or during LAN/USB communication)
Data storageDestination: SD memory card, or internal memory at real time; save interval 1...30 s, 1...60 min, 14 selections;
save items: Measurement value save (average only/average, max./min. value, screen copy (BMP form, saved every 5 min at minimum interval time), waveform save (binary waveform data), PW3360-21 only: Harmonic data save (average only/average, max./min. value in binary format
InterfacesSD/SDHC memory card, LAN 100BASE-TX: HTTP server function, USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: Proportional to active power consumption when measuring integral power consumption, isolated open-collector signal-
FunctionsConnection check, quick set navigation guide, clock, PW3360: Pulse input
Power supplyAC adaptor Z1006, battery Pack 9459AC adapter Z1008, battery pack 9459
Dimensions (mm)180 x 100 x 48 ; 550 g (without PW9002)180 x 100 x 67 ; 830 g (without PW9002)
Safety voltage sensor PW9020-Compatible conductor types: Insulated wires (shielded wires cannot be measured. The product may not be able to accurately measure multi-core cables or cables that have thick insulation); indoor PVC or metal parts.
Compatible conductor diameters finished outer diameter φ6...30 mm.
Effective measurement range 90...520 Veff.
Cord length 3 m

Included: Power logger IM 3360 or 3365, USB cable, instruction manual, measurement guide, color clip set (red, yellow, blue, white) spiral tubes for grouping clamp sensor cords; IM3360 additional power cord L9438-53, AC adaptor Z1006; IM3365 additional safety voltage sensor PW9020, AC adaptor Z1008.