Benefits of the RM354x Series Tester, High-Speed, High-Precision Resistance Meters
- Series of versatile resistance meters for various application focusses.
- Models with high speed, high-accuaracy/precision and multi-channel capabilities.
- Interfaces options depending on model.
HIOKI RM354x Series Resistance Meters
HIOKI RM3542A, RM3543, RM3544, RM3545 Resistance Meters and Testers
The HIOKI RM354x series are resistance testers and high-speed/high-precision resistance meters. The devices offer the setting of the measurement speed to find the optimal spot between high-speed and high-accuracy.
- Resistance meters:
- RM3542: Resistance tester, high-speed resistance meter.
- RM3542A: Resistance meter, high-speed resistance meter.
- RM3543: Resistance tester, high-precision and high-resolution.
- RM3544: Resistance meter, high-precision.
- RM3545: Resistance meter, super-high accuracy and multi-channel capabilities.
- Fastest measurement time 0.9 ms (RM3542, RM3542A), 0.1 ms (RM3543), 18 ms (RM3544), or 2.2 ms (RM3545).
- Finest resolution 0.1 µΩ (RM3542, RM3542A), 0.01 µΩ (RM3543, RM3545), or 1 µΩ (RM3544).
- Testing source current up to 300 mADC (RM3544).
- RM3545: 20 locations multi-point measurement and support for multiplexer unit (version -02).
- Models with interfaces, depending on model RS232C, USB, GPIB.
Model Overview
Model | RM3542 | RM3542A | RM3543 | RM3544 | RM3545 |
Resistance range | At low power OFF: 100 mΩ range (max. 120.0000 mΩ, 0.1 µΩ resolution) to 100 MΩ range (max. 120.0000 MΩ, 100 Ω resolution), 10 steps At low power ON: 1000 mΩ range (max. 1200.000 mΩ, 1 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 4 steps | At low power OFF: 100 mΩ range (max. 120.0000 mΩ, 0.1 µΩ resolution) to 100 MΩ range (max. 120.0000 MΩ, 100 Ω resolution), 16 steps At low power ON: 1000 mΩ range (max. 1200.000 mΩ, 1 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 6 steps | (Method: Four-terminal, constant-current DC) 10 mΩ (max. 12.00000 mΩ, 0.01 µΩ resolution) to 1000 Ω range (max. 1200.000 Ω , 1 mΩ resolution), 7 steps | 30 mΩ (35.000 mΩ display max., 1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display max., 100 Ω resolution), 9 steps | 10 mΩ (12.00000 mΩ display max., 10 nΩ resolution) to 1000 MΩ range (1200.0 MΩ display max., 100 kΩ resolution), 12 steps; low power ON 1000 mΩ (1200.00 mΩ display max., 10 µΩ resolution) to 1000 Ω range (1200.00 Ω display max., 10 mΩ resolution), 4 steps |
Measurement accuracy | With SLOW mode, at 100 mΩ range: ±0.015% rdg. ±0.002% f.s. With SLOW mode, at 1000 Ω range: ±0.006% rdg. ±0.001% f.s. (best case) | At 10 mΩ range, with SLOW mode, average 16 times settings: ±0.060% rdg. ±0.001% f.s. | ±0.020% rdg. ±0.007% f.s. | ±0.006% rdg. ±0.001% f.s. | |
Testing current | 100 mADC (100 mΩ range) to 100 nADC (100 MΩ range) | 1 ADC (10 mΩ range) to 1 mADC (1000 Ω range) | 300 mADC (30 mΩ range) to 500 nADC (3 MΩ range | 1 ADC to 1 µA or less; low power ON: 1 mA to 5 µADC | |
Open-terminal voltage | max. 20 VDC | max. 20 VDC (with applied voltage limit function enabled: max. 10 VDC) | max. 20 VDC (voltage when not measuring is 20 mV or less, with current mode set at pulse and contact improver setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ) | max. 5.5 VDC | 20 VDC(10 kΩ range or more), 5.5 VDC max. (1000 Ω range or less); low power ON: Max. 20 mVDC |
Sampling rate/ measurement speed | FAST, MEDIUM, SLOW, 3 settings At 100 Ω /1000 Ω ranges, with low power OFF: FAST 0.9 ms, MED 3.6 ms, SLOW 17 ms (min. time); Integration time1): 0.1...100.0 ms, or 1...5 PLC at 50 Hz, 1...6 PLC at 60 Hz | FAST, MEDIUM, SLOW; Integration time1): At 10 mΩ range, default value: FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, setting range: 0.1...100.0 ms, or 1...5 PLC at 50 Hz, 1...6 PLC at 60 Hz | FAST 21 ms (50 MHz), 18 ms 60 ms), MED 101 ms, SLOW 401 ms | FAST, MEDIUM, SLOW1, SLOW2, 4 settings; FAST 2.2 ms, MED 21 ms (50 Hz)/18 ms (60 Hz), SLOW1 102 ms, SLOW2 202 ms | |
Other functions | Comparator (compare setting value with measurement value), delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), measurement fault detection, probe short-circuit detection, improve contact, auto-memory, statistical calculations, settings monitor (when using two instruments, a difference in settings causes warning notification), retry, trigger function. etc. | Comparator (compare setting value with measurement value), delay, OVC (offset voltage compensation), average, measurement fault detection, probe short-circuit detection, improve contact, current mode setting (a pulse application function that applies current only during measurement), auto-memory, statistical calculations, settings monitor (when using two instruments, a difference in settings causes warning notification), retry, trigger function, etc. | Temperature correction, comparator (ABS/REF%), key-lock (OFF, menu lock, all lock), display digit count selection function (5 digits/4 digits), automatic power supply frequency settings (AUTO/50 Hz/60 Hz), scaling, judgment sound setting, auto hold, averaging, panel store/panel load | Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), display digit count selection function (7 digit/6 digit/5 digit), automatic power supply frequency settings (AUTO/50 Hz/60 Hz), scaling, judgment sound setting, auto hold, averaging, statistical calculations, panel store/panel load, D/A output | |
- | applied voltage limit function, scaling function | ||||
Temperature measurement | - | - | With sensor Z2001: -10.0...99.9°C, accuracy ±0.5°C (temperature sensor Z2001 and RM3544 combined accuracy | - | |
Multiplexer | - | - | - | Only RM3545-02, support unit Z3003 (install up to 2 units) | |
Display | Monochrome graphic LCD 240x64 dot, white LED backlight | ||||
Interfaces | RS232C, printer, external I/O, versions -01: Additional GP-IB | Optional: RS232C, printer (RS232C), USB | RS232C, printer (RS232C), USB, version -01: Additional GPIB | ||
Dimensions (mm) | 260 x 88 x 300; approx. 2.9 kg | 260 x 88 x 300; approx. 3 kg | 215 x 80 x 166; 0.9 kg (RM3544), 1.0 kg (RM3544-01) | 215 x 80 x 307; 2.5 kg (RM3545/RM3545-01), 3.2 kg (RM3545-02) | |
Versions | RM3542: Resistance tester, high-speed resistance meter RM3542-01: With built-in GPIB | RM3542-50: Resistance meter, high-speed resistance meter RM3542-51: With built-in GPIB | RM3543: Resistance tester RM3543-01: With built-in GPIB | RM3544: Resistance meter, no interfaces RM3544-01: With built in EXT I/O, RS232C, USB interface | RM3545: Resistance meter RM3545-01: With built-in GPIB RM3545-02: Support for the multiplexer unit |
1) PLC = one power line cycle/mains wave-form period.
Included: Resistance meter RM 3542, 3542A, 3543, 3544, or 3545, power cord, instructions maual, operation guide, models with EXT I/O: EXT I/O male connector.
Additional accessories included:
RM3544: Clip type lead L2101, spare fuse
RM3544-01: Application CD, USB cable (A-to-B type), spare fuse
RM3545: Clip type lead L2101, temperature sensor Z2001, application CD, USB cable (A-to-B type), spare fuse.