ITECH IT7900 Regenerative Grid Simulator

min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Benefits of the IT7900 1- and 3-Phase Grid Simulator

  • Up to 15 kVA in 3-U size; up to 960 kVA.
  • Regenerative capability.
  • Touch-panel operation.

ITECH IT7900 Regenerative Grid Simulator

The IT7900 series is a programmable, four-quadrant grid simulator. It can also operate as a four-quadrant power amplifier which can be used to test various grid-connected equipment, such as PCS, energy storage system, microgrid, BOBC (V2X), PHiL, etc. With the islanding mode (RLC settable), a single IT7900 unit can realize the anti-islanding protection test. The IT7900 series offers up to 15 kVA in 3U size, with parallel connection power can be extended to max. 960 kVA.

  • Up to 15 kVA in 3U rack space, 16...150 Hz.
  • Regenerative grid simulator and full 4-quadrant AC/DC power sources.
  • Power amplifier function for PHiL applications.
  • Professional anti-islanding test mode, can set and simulate the RLC (resistive-inductive-capacitive), active and reactive power circuit for anti-islanding detection.
  • Three working modes CV/current limit/power limit.
  • AC, DC, AC+DC or DC+AC output capability.
  • Comprehensive working modes selectable: Single-phase, three-phase, reversed phase and multi-channel (2,5 kVA model only single-phase).
  • Programmable output impedance, allows simulation of real-world utility grid impedance (on request).
  • Compliance tests incl. LVRT/phase jump/frequency variation/harmonic injection.
  • Supported regulatory testing include IEC61000-4-11/4-13/4-14/4-28 etc.
  • Wide voltage ranges: 350 V L-N and 500 V L-N (on request).
  • Master-slave parallel with current sharing technology, up to 960 kVA.
  • Intuitive touch screen; built-in single/3-phase AC power meter; scope function.
  • Fast response time and high accuracy 0.1% + 0.2%FS.
  • Waveforms library : Sine, square, triangle, clipped sine, trapezoidal, self-defined.
  • Harmonics and interharmonics waveform synthesizer.
  • Power line disturbance simulation testing by LIST programming/sweep/Surge and Sag functions.
  • The harmonic measurement function can measure 50th order harmonics of voltage and current (voltage and current harmonic analysis, voltage harmonic simulation).
  • Output 0...360° start/stop phase angle can be set.
  • Front panel USB port for data and waveform import and export.
  • Provides various trigger input/output signals. When amplitude/frequency changes, trigger signals can be generated to synchronously capture the current waveform of DUTs.
  • Relay CTRL function, to cut off the connection between instrument and DUT.
  • Frequency lock and phase lock function, tracking the external signal frequency and phase, to achieve 6-phase and 12-phase power output.
  • Built-in USB, CAN, Ethernet/LAN, digital-I/O interface, optional GPIB, analog, and RS232.

Model Overview - the Complete Series

SeriesMain functionLoad functionForm factor
IT79004-quadrant regenerative grid simulator starting at 5 kVA, up to 960 kVA via master-slave configurationNo AC/DC electronic load function (sink mode)15 kVA in 3U form factor (5 kVA single-phase and 6 kVA and above, single- and three-phase)
IT7900E4-quadrant regenerative grid simulator, extended version of the IT7900 series, starting at 21 kVA and up to 10 MVA via master-slaveNo AC/DC electronic load function (sink mode)Compact design, 21 kVA – 3U
IT7900PGrid simulator with regenerative AC/DC load, starting at 5 kVA, max. 960 kVA via master-slaveIntegrated regenerative load function with RLC load15 kVA in a 3U design, (5 kVA single-phase and 6 kVA and up, single- and three-phase)
IT7900EPAdvanced high-performance version of the IT7900P series, starting at 21 kVA and up to 10 MVA via master-slaveIntegrated regenerative load function with RLC loadCompact design, 21 kVA in 3U

Model Overview - all Models

IT7900 regenerative grid simulator
ModelVoltageCurrentPowerResolutionAccuracyInterfacesSize
IT79120-350-720350 V720 A120 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.USB,
CAN,
LAN/Ethernet,
digital-I/O-port,
optional GPIB,
optional analog,
optional RS232
37U
IT79105-350-630350 V630 A05 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7990-350-540350 V540 A90 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7975-350-450350 V450 A75 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7960-350-360350 V360 A60 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7945-350-270350 V270 A45 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.15U
IT7930-350-180350 V180 A30 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.6U
IT7915-350-90350 V90 A15 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.3U
IT7912-350-90350 V90 A12 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.3U
IT7909-350-90350 V90 A9 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.3U
IT7906-350-90350 V90 A6 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.3U
IT7905-350-30U350 V30 A5 kVA0.01 V/0.01 A<0.01% + 0.01% F.S./<0.3% + 0.3% F.S.3U
IT79165-350-990350 V990 A165 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79150-350-900350 V900 A150 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79135-350-810350 V810 A135 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT7900 regenerative grid simulator - high voltage
ModelVoltageCurrentPowerResolutionAccuracyInterfacesSize
IT79270-700-270700 V270 A270 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.USB,
CAN,
LAN/Ethernet,
digital-I/O-port,
optional GPIB,
optional RS232
27U*3
IT79180-700-180700 V180 A180 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*2
IT7990-700-90700 V90 A90 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U
IT79810-1050-5401050 V540 A810 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U*6
IT79675-1050-4501050 V450 A675 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U*5
IT79540-1050-3601050 V360 A540 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U*4
IT79405-1050-2701050 V270 A405 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U*3
IT79270-1050-1801050 V180 A270 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U*2
IT79135-1050-901050 V90 A135 kVA0.1 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.37U
IT79900-700-900700 V900 A900 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*10
IT79810-700-810700 V810 A810 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*9
IT79720-700-720700 V720 A720 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*8
IT79630-700-630700 V630 A630 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*7
IT79540-700-540700 V540 A540 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*6
IT79450-700-450700 V450 A450 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*5
IT79360-700-360700 V360 A360 kVA0.01 V/0.01 A<0.1% + 0.2% F.S./<0.2% + 0.3% F.S.27U*4
IT7900 regenerative grid simulator - E-series
ModelVoltageCurrentPowerResolutionAccuracyInterfacesSize
IT79126E-350-630350 V630 A126 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.USB,
CAN,
LAN/Ethernet,
digital-I/O-port
optional GPIB,
optional analog,
optional RS232
27U
IT79105E-350-525350 V525 A105 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7984E-350-420350 V420 A84 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7963E-350-315350 V315 A63 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.15U
IT7942E-350-210350 V210 A42 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.6U
IT7921E-350-105350 V105 A21 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT7900 regenerative grid simulator - EP-series
ModelVoltageCurrentPowerResolutionAccuracyInterfacesSize
IT79105EP-350-525350 V525 A105 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.USB,
CAN,
LAN/Ethernet,
digital-I/O-port,
optional GPIB,
optional analog,
optional RS232
27U
IT7984EP-350-420350 V420 A84 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7963EP-350-315350 V315 A63 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.15U
IT7942EP-350-210350 V210 A42 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.6U
IT7921EP-350-105350 V105 A21 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT79126EP-350-630350 V630 A126 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7900 regenerative grid simulator - P-series
ModelVoltageCurrentPowerResolutionAccuracyInterfacesSize
IT7915P-350-90350 V90 A15 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.USB,
CAN,
LAN/Ethernet,
digital-I/O-port,
optional GPIB,
optional analog,
optional RS232
3U
IT7912P-350-90350 V90 A12 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT7909P-350-90350 V90 A9 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT7906P-350-90350 V90 A6 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT7905P-350-30U350 V30 A5 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.3U
IT79165P-350-990350 V990 A165 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79150P-350-900350 V900 A150 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79135P-350-810350 V810 A135 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79120P-350-720350 V720 A120 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.37U
IT79105P-350-630350 V630 A105 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7990P-350-540350 V540 A90 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.3% + 0.3% F.S.27U
IT7975P-350-450350 V450 A75 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7960P-350-360350 V360 A60 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.27U
IT7945P-350-270350 V270 A45 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.15U
IT7930P-350-180350 V180 A30 kVA0.01 V/0.01 A<0.1% + 0.1% F.S./<0.1% + 0.2% F.S.6U