Tekbox TBISN-T4 Two Balanced Pairs ISN
Tekbox TBISN-T4 Two Balanced Pairs ISN
The Tekbox TBISN-T4 are two balanced telecom pairs ISN for conducted emissions test per CISPR 22 on two balanced pair telecom lines. The TBISN-T4 meets the requirements for Longitudinal Conversion Loss defined in CISPR 22 item 9.6.2.c)1) page 24 accepted by CISPR.
Per CISPR 22 (2005), ISNs are specialized coupling decoupling devices used for measuring the conducted asymmetric common mode radio interference voltages of ITE.
- Frequency range 150 kHz...30 MHz.
- Impedance (asymmetric) 150 Ω ±20 Ω.
- Phase (asymmetric) 0° ±20°.
- Longitudinal Conversion Loss (LCL) CISPR 22 item 9.6.2.c)1) page 24.
- Voltage Division Ratio (VDF) for asymmetrical voltage 10 dB ±1 dB.
- EuT, AE terminals: D-sub 25.
Measuring port: 50 Ω BNC. - Max. voltage: 63 VAC/100 VDC;
max. current: 250 mA. - Insertion loss (differential mode) <3 dB.
- Decoupling AE-EuT 150 kHz...1.5 MHz >(35...55 dB); >1.5 MHz (>55 dB).
- Outer dimensions (WxHxD, mm): 100 x 100 x 235; approx. 1.0 kg.
- According to standards CISPR 16-1-2, CISPR 22, CISPR 32, and CISPR 15.
- Operating temperature +5...+40°C; relative humidity up to 80%.
Information on product safety:
Manufacturer:
TekBox Digital Solutions Vietnam Co. Ltd., Saigon Hi-Tech Park, Factory 4, 4F, Lot I-3B-1, N6 Street, Thu Duc City, 700 000 Ho Chi Minh City/VNM
www.tekbox.com
Responsible person:
Meilhaus Electronic GmbH, Am Sonnenlicht 2, 82239 Alling/DEU
info@meilhaus.com