Benefits of the FLIR EM54 Measurement Instrument for Air Velocity, Airflow, Air Temperature, Relative Humidity

  • Combination environmental meter for HVAC experts.
  • Measures air velocity, airflow, air temperature, relative humidity.
  • Dew point (calculated), wet bulb (calculated) and contact temperature (thermocouple).

FLIR EM54 Environmental Meter

The FLIR EM54 combination environmental meter is the ideal and cost-effective tool for HVAC professionals. It is used for troubleshooting and testing air duct systems in buildings of all types (residential, commercial and industrial). The EM54 verifies that the inlet and outlet ducts are delivering the specified airflow. In addition, the EM54 measures or calculates humidity, wet bulb and dew point. The included thermocouple can also be used to check electric motors and thermal system components for proper operating temperature.

  • Measures air velocity, air flow, air temperature, relative humidity.
  • Measures/calculates dew point and wet bulb.
  • Measures contact temperature with type K thermocouple probe.
  • External high resolution vane anemometer probe with ranges 0.4...30 m/s, 1.4...108 km/h, 0.8...58.3 knots.
  • Airflow 0...999900 CMM (0...999900 CFM).
  • Air temperature -30...60°C.
  • Relative humidity 5...98%.
  • Dew point (calculated) -30...60°C.
  • Wet bulb (calculated) -30...50°C.
  • Contact temperature (type-K thermocouple probe) -99.9...+1372°C.
  • Backlit LCD multifunction display.
  • Power supply: 1x 9 V battery; battery life 120 h under normal operating conditions.
  • Automatic power off (APO) configurable in 8 steps from 5 to 60 min.
  • Operating temperature 0...50°C.
  • Drop resistance test 1 m (without removable probes).
  • Dimensions main unit 275 mm x 65 mm x 45 mm, 284 g (incl. battery, without external probes); housing length anemometer 150 mm; cable length anemometer 950 mm; diameter impeller anemometer probe 70 mm.

Included: EM54 environmental measuring instrument, vane anemometer probe, type K thermocouple probe, soft carrying case, 9-V battery, tripod.