Keysight Battery Drain Analyzer Module N6785A

Scaled Prices
taking 1 pc.
€ 12.297,46
taking 2 pc.
€ 11.682,59
12.297,46
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Item available at short notice. Delivery Time ~10-25 workdays
Item available at short notice. Delivery Time ~10-25 workdays
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Keysight Battery Drain Analyzer Module N6785A

For Keysight N6700C, N6701C, N6702C, N6705C:

  • Basic DC power modules.
  • High-performance,autoranging and precision DC power modules.
  • Source/measure units (SMUs) and application-specific modules.

Model Overview

Model Voltage Current Power Description
Source/measure units (SMUs) and application-specific modules
▸N6781A 600 mV, 6, 20 V ±300 mA, 1, 3 A 1.8, 18, 20 W 2-quadrant source/measure unit for battery drain analysis, 1 slot wide. 3 voltage measurement ranges, seamless ranging down to 1 mA FS range with 100 nA max. offset error, 10 µA FS range (fixed range)
▸N6782A 20 V ±3 A 20 W 2-quadrant source/measure unit for functional test, 1 slot wide.
▸N6783A-MFG 6 V +3 A/-2 A 18 W Mobile communications DC power module (basic 2-quadrant)
▸N6783A-BAT 8 V +3 A/-2 A 24 W Battery charge/discharge module (basic 2-quadrant)
▸N6784A ±20 V 3 A 20 W 4-quadrant general-purpose source/measure unit
▸N 6785A ±6, 10, 15, 20 V ±4, 5, 6.7, 8 A 48, 67, 75, 80 W Battery drain analyzer module, included DVM and programmable resistance, 2 slots wide. One voltage measurement range (0...20 V), seamless ranging down to 1 mA FS range with 100 nA max. offset error; 10 µA FS range not available
▸N6786A ±6, 10, 15, 20 V ±4, 5, 6.7, 8 A 48, 67, 75, 80 W Functional test module (no DVM, no programmable resistance), 2 slots wide