Model | Bandwidth | Attenuation | Impedance | Remarks |
▸PB470 | 6 MHz/70 MHz | 10:1 | 85/18 pF, 1 MΩ/10 MΩ | 300 V/600 V |
▸PB925 | 250 MHz | 10:1 | 16 pF/10 MΩ | CAT II 1000 V, CAT III 600 V; SHS handheld oscilloscope option |
▸PP510 | 6 MHz/100 MHz | 10:1 | 85/18 pF, 1 MΩ/10 MΩ | 300 V/600 V; SHS handheld oscilloscope option |
▸PP215 | 6 MHz/200 MHz | 10:1 | 85/16 pF, 1 MΩ/10 MΩ | 300 V/600 V; SHS handheld oscilloscope option |
▸SP2035 | 350 MHz | 10:1 | 12 pF, 10 MΩ | CAT II 300 VRMS |
▸SP2035A | 350 MHz | 10:1 | 12 pF, 10 MΩ | CAT II 300 VRMS |
▸SP3050A | 500 MHz | 10:1 | 11 pF, 10 MΩ | CAT II 400 VRMS |
▸SP5050A | 500 MHz | 10:1 | 12 pF, 10 MΩ | CAT II 300 VRMS; cable length 130 cm |
▸SP3150A | 500 MHz | 10:1 | 11 pF, 10 MΩ | CAT II 400 VRMS; for SDS6000A only |
▸SP6150A | 1.5 GHz | 10:1 | 1.8 pF/500 Ω | Max. 8.5 V |
▸HPB4010 | 40 MHz | 1000:1 | n. s | Max. measurement voltage DC: 10 kV, ACRMS: 7 kV (sine), ACPP: 20 kV (pulse) |
Overview Siglent Active Probes- Single-Ended and Differential
Model Overview
Siglent Active, Differential and High Voltage Probes
Model | Bandwidth | Attenuation | Impedance | Remarks | Differential |
▸DPB1300 | 50 MHz | 50:1/500:1 | <4 pF/5 MΩ (single-ended), <2 pF/10 MΩ (two inputs) | Rise time ≤7 ns, DC accuracy ±2%, max. input 600 V CAT III, 1000 V CAT II, max. differential test voltage (DC + peak AC) 50X: ±130 V/500 X: ±1300 V, DC 12 V/1.2 A power | ✓ |
▸DPB5150 | 70 MHz | 50:1/500:1 | >4 pF/5 MΩ (single-ended to GND), >2 pF/10 MΩ (two inputs) | Max. input differential voltage 1500 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor | ✓ |
▸DPB5150A | 100 MHz | 50:1/500:1 | >4 pF/5 MΩ (single-ended to GND), >2 pF/10 MΩ (two inputs) | Max. input differential voltage 1500 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor | ✓ |
▸DPB5700 | 70 MHz | 100:1/1000:1 | >5 pF/20 MΩ (single-ended to GND), >2.5 pF/40 MΩ (two inputs) | Max. input differential voltage 7000 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor | ✓ |
▸DPB5700A | 100 MHz | 100:1/1000:1 | >5 pF/20 MΩ (single-ended to GND), >2.5 pF/40 MΩ (two inputs) | Max. input differential voltage 7000 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor | ✓ |
▸SAP1000 | 1 GHz | 10:1 | 1.2 pF/1 MΩ | SAPBus interface | - |
▸SAP2500 | 2.5 GHz | 10:1 | 1.1 pF/1MΩ | SAPBus interface | - |
▸SAP2500D | 2.5 GHz | 10:1 | 1.0 pF/200 kΩ (differential), 100 kΩ (single-ended), 50 kΩ (common mode) | Differential, SAPBus interface | ✓ |
▸SAP4000P | 4 GHz | 1.1:1 | Low frequency resistance 20 kΩ, high frequency resistance 50 Ω | Power rail probe; offset range ±24 V; dynamic range ±600 mV | - |
▸SAP5000D | 5 GHz | 10:1 | 400 fF/single-ended 10 kΩ, differential 20 kΩ | Differential, offset range ±12 V; dynamic range ±2.5 V; damage voltage 20 V | ✓ |
Overview Siglent Current Probes
Model Overview
Model | Bandwidth | Current | Remarks |
▸CP4020 | 100 kHz | 20 ARMS (continuous)/60 A (peak) | Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...60 APK ±2%; 9 V battery-powered |
▸CP4050 | 1 MHz | 50 ARMS (continuous)/140 A (peak) | Switching ratio 500 mV/A, 50 mV/A, DC accuracy 500 mV/A (20 mA...14 APK) ±3% ±20 mA, 50 mV/A (200 mA...100 APK) ±4% ±200 mA, 50 mV/A (100...140 APK) ±15% max; 9 V battery-powered |
▸CP4070 | 150 kHz | 70 ARMS (continuous)/200 A (peak) | Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...200 APK) ±2%, 9 V battery-powered |
▸CP4070A | 300 kHz | 70 ARMS (continuous)/200 A (peak) | Switching ratio 100 mV/A, 10 mV/A, DC accuracy 100 mV/A (50 mA...10 APK) ±3% ±50 mA, 10 mV/A (500 mA...40 APK) ±4% ±50 mA, 1 0mV/A (40...200 APK) ±15% max; 9 V battery powered |
▸CP6030 | 50 MHz | 30 ARMS (continuous)/50 A (peak) | Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor |
▸CP6030A | 100 MHz | 30 ARMS (continuous)/50 A (peak) | Switching ratio 5 A/30 A, accuracy 5 A ( ±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor |
▸CP6150 | 12 MHz | 150 ARMS (continuous)/300 A (peak) | Switching ratio 30 A/150A, accuracy 30 A (±1% ±10 mA), 150 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor |
▸CP6500 | 5 MHz | 500 ARMS (continuous)/750 A (peak) | Switching ratio 75 A/500A, accuracy 75 A (±1% ±10 mA), 500 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor |
▸CPL5100 | DC...600 kHz | L 50 mA...10 A (peak), H 1...100 A (peak) | Attenuation accuracy L 0.1 V/A), H 0.01 V/A, typical DC precision L 3% ±50 mA, H 500 A...40 A, peak 4% ±50 mA (40...100 APK, ±15% max., rise time ≤583 ns, operating voltage RMS: CAT I 600 V CAT II 600 V CAT III 300 V; 9 V alkaline layer-built battery |
▸SCP5030 | DC...50 MHz | 30 ARMS (continuous)/50 A (peak) | Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface |
▸SCP5030A | DC...100 MHz | 30 ARMS (continuous)/50 A (peak) | Switching ratio 5 A/30 A, accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface |
▸SCP5150 | DC...12 MHz | 150 ARMS (continuous)/300 A (peak) | Switching ratio 30 A/150 A; accuracy 30 A (±1% ±10 mA)/150 A (±1% ±100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface |
▸SCP5500 | DC...2 MHz | 500 ARMS (continuous)/750 A (peak) | Switching ratio 75 A/500 A; accuracy 75 A (±1% ±10 mA)/500 A (±1%± 100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface |
Overview Siglent Fiber Isolated Probes
Model Overview
Information on product safety:
Manufacturer:
SIGLENT Technologies CO., LTD., Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101/CHN
www.siglent.com