Siglent CP Series Current Probes

Model Overview

ModelBandwidthCurrentRemarks
CP4020100 kHz20 ARMS (continuous)/60 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...60 APK ±2%; 9 V battery-powered
CP40501 MHz50 ARMS (continuous)/140 A (peak)Switching ratio 500 mV/A, 50 mV/A, DC accuracy 500 mV/A (20 mA...14 APK) ±3% ±20 mA, 50 mV/A (200 mA...100 APK) ±4% ±200 mA, 50 mV/A (100...140 APK) ±15% max; 9 V battery-powered
CP4070150 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...200 APK) ±2%, 9 V battery-powered
CP4070A300 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 100 mV/A, 10 mV/A, DC accuracy 100 mV/A (50 mA...10 APK) ±3% ±50 mA, 10 mV/A (500 mA...40 APK) ±4% ±50 mA, 1 0mV/A (40...200 APK) ±15% max; 9 V battery powered
CP603050 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
CP6030A100 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A, accuracy 5 A ( ±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
CP615012 MHz150 ARMS (continuous)/300 A (peak)Switching ratio 30 A/150A, accuracy 30 A (±1% ±10 mA), 150 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
CP65005 MHz500 ARMS (continuous)/750 A (peak)Switching ratio 75 A/500A, accuracy 75 A (±1% ±10 mA), 500 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
CPL5100DC...600 kHzL 50 mA...10 A (peak), H 1...100 A (peak)Attenuation accuracy L 0.1 V/A), H 0.01 V/A, typical DC precision L 3% ±50 mA, H 500 A...40 A, peak 4% ±50 mA (40...100 APK, ±15% max., rise time ≤583 ns, operating voltage RMS: CAT I 600 V CAT II 600 V CAT III 300 V; 9 V alkaline layer-built battery

Overview Siglent Current Probes

ModelBandwidthCurrentRemarks
▸CP4020100 kHz20 ARMS (continuous)/60 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...60 APK ±2%; 9 V battery-powered
▸CP40501 MHz50 ARMS (continuous)/140 A (peak)Switching ratio 500 mV/A, 50 mV/A, DC accuracy 500 mV/A (20 mA...14 APK) ±3% ±20 mA, 50 mV/A (200 mA...100 APK) ±4% ±200 mA, 50 mV/A (100...140 APK) ±15% max; 9 V battery-powered
▸CP4070150 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...200 APK) ±2%, 9 V battery-powered
▸CP4070A300 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 100 mV/A, 10 mV/A, DC accuracy 100 mV/A (50 mA...10 APK) ±3% ±50 mA, 10 mV/A (500 mA...40 APK) ±4% ±50 mA, 1 0mV/A (40...200 APK) ±15% max; 9 V battery powered
▸CP603050 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
▸CP6030A100 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A, accuracy 5 A ( ±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
▸CP615012 MHz150 ARMS (continuous)/300 A (peak)Switching ratio 30 A/150A, accuracy 30 A (±1% ±10 mA), 150 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
▸CP65005 MHz500 ARMS (continuous)/750 A (peak)Switching ratio 75 A/500A, accuracy 75 A (±1% ±10 mA), 500 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
▸CPL5100DC...600 kHzL 50 mA...10 A (peak), H 1...100 A (peak)Attenuation accuracy L 0.1 V/A), H 0.01 V/A, typical DC precision L 3% ±50 mA, H 500 A...40 A, peak 4% ±50 mA (40...100 APK, ±15% max., rise time ≤583 ns, operating voltage RMS: CAT I 600 V CAT II 600 V CAT III 300 V; 9 V alkaline layer-built battery
▸SCP5030DC...50 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5030ADC...100 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A, accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5150DC...12 MHz150 ARMS (continuous)/300 A (peak)Switching ratio 30 A/150 A; accuracy 30 A (±1% ±10 mA)/150 A (±1% ±100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5500DC...2 MHz500 ARMS (continuous)/750 A (peak)Switching ratio 75 A/500 A; accuracy 75 A (±1% ±10 mA)/500 A (±1%± 100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface