Siglent Probes - Overview

Siglent Probes - Overview
min Quantity
1 piece
Unit price
base price
Overview page
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Siglent Probes - Overview

Depending on the model, recommended for Siglent oscilloscopes and other brands.

Overview Siglent Passive Probes

Model Overview

ModelBandwidthAttenuationImpedanceRemarks
▸PB4706 MHz/70 MHz10:185/18 pF, 1 MΩ/10 MΩ300 V/600 V
▸PB925250 MHz10:116 pF/10 MΩCAT II 1000 V, CAT III 600 V; SHS handheld oscilloscope option
▸PP5106 MHz/100 MHz10:185/18 pF, 1 MΩ/10 MΩ300 V/600 V; SHS handheld oscilloscope option
▸PP2156 MHz/200 MHz10:185/16 pF, 1 MΩ/10 MΩ300 V/600 V; SHS handheld oscilloscope option
▸SP2035350 MHz10:112 pF, 10 MΩCAT II 300 VRMS
▸SP2035A350 MHz10:112 pF, 10 MΩCAT II 300 VRMS
▸SP3050A 500 MHz10:111 pF, 10 MΩCAT II 400 VRMS
▸SP5050A500 MHz10:112 pF, 10 MΩCAT II 300 VRMS; cable length 130 cm
▸SP3150A500 MHz10:111 pF, 10 MΩCAT II 400 VRMS; for SDS6000A only
▸SP6150A1.5 GHz10:11.8 pF/500 ΩMax. 8.5 V
▸HPB401040 MHz1000:1n. sMax. measurement voltage DC: 10 kV, ACRMS: 7 kV (sine), ACPP: 20 kV (pulse)

Overview Siglent Active Probes- Single-Ended and Differential

Model Overview

Siglent Active, Differential and High Voltage Probes

ModelBandwidthAttenuationImpedanceRemarksDifferential
▸DPB130050 MHz50:1/500:1<4 pF/5 MΩ (single-ended), <2 pF/10 MΩ (two inputs)Rise time ≤7 ns, DC accuracy ±2%, max. input 600 V CAT III, 1000 V CAT II, max. differential test voltage (DC + peak AC) 50X: ±130 V/500 X: ±1300 V, DC 12 V/1.2 A power
▸DPB515070 MHz50:1/500:1>4 pF/5 MΩ (single-ended to GND), >2 pF/10 MΩ (two inputs)Max. input differential voltage 1500 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor
▸DPB5150A100 MHz50:1/500:1>4 pF/5 MΩ (single-ended to GND), >2 pF/10 MΩ (two inputs)Max. input differential voltage 1500 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor
▸DPB570070 MHz100:1/1000:1>5 pF/20 MΩ (single-ended to GND), >2.5 pF/40 MΩ (two inputs)Max. input differential voltage 7000 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor
▸DPB5700A100 MHz100:1/1000:1>5 pF/20 MΩ (single-ended to GND), >2.5 pF/40 MΩ (two inputs)Max. input differential voltage 7000 V (DC + peak AC), accuracy ±2%, standard 5 V/1 A USB power adaptor
▸SAP10001 GHz10:11.2 pF/1 MΩSAPBus interface-
▸SAP25002.5 GHz10:11.1 pF/1MΩSAPBus interface-
▸SAP2500D2.5 GHz10:11.0 pF/200 kΩ (differential), 100 kΩ (single-ended), 50 kΩ (common mode)Differential, SAPBus interface
▸SAP4000P4 GHz1.1:1Low frequency resistance 20 kΩ, high frequency resistance 50 ΩPower rail probe; offset range ±24 V; dynamic range ±600 mV-
▸SAP5000D5 GHz10:1400 fF/single-ended 10 kΩ, differential 20 kΩDifferential, offset range ±12 V; dynamic range ±2.5 V; damage voltage 20 V

Overview Siglent Current Probes

Model Overview

ModelBandwidthCurrentRemarks
▸CP4020100 kHz20 ARMS (continuous)/60 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...60 APK ±2%; 9 V battery-powered
▸CP40501 MHz50 ARMS (continuous)/140 A (peak)Switching ratio 500 mV/A, 50 mV/A, DC accuracy 500 mV/A (20 mA...14 APK) ±3% ±20 mA, 50 mV/A (200 mA...100 APK) ±4% ±200 mA, 50 mV/A (100...140 APK) ±15% max; 9 V battery-powered
▸CP4070150 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 50 mV/A, 5 mV/A, DC accuracy 50 mV/A (0.4...10 APK) ±2%, 5 mV/A (1...200 APK) ±2%, 9 V battery-powered
▸CP4070A300 kHz70 ARMS (continuous)/200 A (peak)Switching ratio 100 mV/A, 10 mV/A, DC accuracy 100 mV/A (50 mA...10 APK) ±3% ±50 mA, 10 mV/A (500 mA...40 APK) ±4% ±50 mA, 1 0mV/A (40...200 APK) ±15% max; 9 V battery powered
▸CP603050 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
▸CP6030A100 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A, accuracy 5 A ( ±1% ±1 mA), 30 A (±1% ±10 mA), standard DC 12 V/1.2 A power adaptor
▸CP615012 MHz150 ARMS (continuous)/300 A (peak)Switching ratio 30 A/150A, accuracy 30 A (±1% ±10 mA), 150 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
▸CP65005 MHz500 ARMS (continuous)/750 A (peak)Switching ratio 75 A/500A, accuracy 75 A (±1% ±10 mA), 500 A (±1% ±100 mA), standard DC 12 V/1.2 A power adaptor
▸CPL5100DC...600 kHzL 50 mA...10 A (peak), H 1...100 A (peak)Attenuation accuracy L 0.1 V/A), H 0.01 V/A, typical DC precision L 3% ±50 mA, H 500 A...40 A, peak 4% ±50 mA (40...100 APK, ±15% max., rise time ≤583 ns, operating voltage RMS: CAT I 600 V CAT II 600 V CAT III 300 V; 9 V alkaline layer-built battery
▸SCP5030DC...50 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A; accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5030ADC...100 MHz30 ARMS (continuous)/50 A (peak)Switching ratio 5 A/30 A, accuracy 5 A (±1% ±1 mA)/30 A (±1% ±10 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5150DC...12 MHz150 ARMS (continuous)/300 A (peak)Switching ratio 30 A/150 A; accuracy 30 A (±1% ±10 mA)/150 A (±1% ±100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface
▸SCP5500DC...2 MHz500 ARMS (continuous)/750 A (peak)Switching ratio 75 A/500 A; accuracy 75 A (±1% ±10 mA)/500 A (±1%± 100 mA); SAPBUS interface, powered by oscilloscope through SAPBUS interface

Overview Siglent Fiber Isolated Probes

Model Overview

ModelBandwidthAttenuation (options)VoltagePower supply
▸ODP6050B500 MHz5:1/10:1/20:1/50:1/100:1/200:1/500:1Max. diff. test voltage (DC + AC peak) ±25 V, isolated voltage ±60 kVExternal DC 5 V adaptor or 7.4 V battery
▸ODP6100B1 GHz


Information on product safety:

Manufacturer:
SIGLENT Technologies CO., LTD., Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101/CHN
www.siglent.com
(EU branch Germany)