Keysight Probes - Overview
Depending on the model, recommended for Keysight oscilloscopes of the series InfiniiVision EDUX (A, G), 1000 X (A, G), 2000 X (A), 3000 X (A, G, T), 4000 X (A, G), 6000 X (A), HD3, EXR, Infiniium S, and others.
Overview Keysight Passive Probes
Model Overview
Model | Cable length | Attenuation | Typical probe bandwidth | Compensates oscilloscope input | Max. input voltage, other specs | Recommended oscilloscopes (examples) |
▸10070D | 1.5 m | 1:1 | 20 MHz | 1 MΩ, approx. 70 pF | 400 V CAT II calculated rise time <17.5 ns | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸10073D | 1.5 m | 10:1 | 500 MHz | 1 MΩ, 6...15 pF | 400 V CAT II | |
▸10074D | 1.5 m | 10:1 | 150 MHz | 1 MΩ, 9...17 pF | 400 V CAT II | |
▸10076C | 1.8 m | 100:1 | 500 MHz | 1 MΩ, 7...20 pF | 3.7 kVpeak mains isolated, 1 kVpeak CAT II calculated rise time <0.7 ns | 1000 X, 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2140A | 1.2 m | 1:1/10:1 | 200 MHz | 1 MΩ, 15...40 pF | 300 V at 10:1, 150 V at 1:1 CAT II | 1000 X |
▸N2142A | 1.2 m | 1:1/10:1 | 75 MHz | 1 MΩ, 15...40 pF | 300 V at 10:1, 150 V at 1:1 CAT II | 1000 X |
▸N2840A | 1.2 m | 10:1 | 50 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | |
▸N2841A | 1.2 m | 10:1 | 150 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | 2000 X, 3000 X |
▸N2842A | 1.2 m | 10:1 | 300 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | 2000 X, 3000 X |
▸N2843A | 1.3 m | 10:1 | 500 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2870A | 1.3 m | 1:1 | 35 MHz | 1 MΩ | 55 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2871A | 1.3 m | 10:1 | 200 MHz | 1 MΩ, 10...25 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2872A | 1.3 m | 10:1 | 350 MHz | 1 MΩ, 10...25 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2873A | 1.3 m | 10:1 | 500 MHz | 1 MΩ, 10...25 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸N2874A | 1.3 m | 10:1 | 1.5 GHz | 50 &Omega: | 8.5 V CAT I | 4000 X, 6000 X und alle Infiniium series |
▸N2875A | 1.3 m | 20:1 | 500 MHz | 1 MΩ, 7...20 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X |
▸N2876A | 1.3 m | 100:1 | 1.5 GHz | 50 &Omega: | 21 V mains isolated | 4000 X, 6000 X und alle Infiniium series |
▸N2889A | 1.3 m | 1:1/10:1 | 350 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X |
▸N2890L | 1.3 m | 10:1 | 500 MHz | 1 MΩ, 5...30 pF | 300 V CAT II | 2000 X, 3000 X, 4000 X, 6000 X |
▸N2894A | 1.3 m | 10:1 | 700 MHz | 1 MΩ, 10...25 pF | 300 V CAT II | 4000 X and 6000 X |
▸N7007A | 2 m | 10:1 | 400 MHz | 1 MΩ, 8...16 pF | 1 kV CAT II, 600 V CAT III | 2000 X, 3000 X, 4000 X, 6000 X, S series |
▸PP0001A | 1.3 m | Variable | 1 GHz | 10 MΩ/4.0 pF | 300 V CAT II; 5 mm tip | InfiniiVision series, EXR, Infiniium series |
▸PP0002A | 1.3 m | Variable | 800 MHz | 40 MΩ/2.0 pF | 1200 V CAT II; 5 mm tip | InfiniiVision series, EXR, Infiniium series |
▸PP0003A | 1.3 m | Variable | 1 GHz | 10 MΩ/4.0 pF | 30 V CAT II; MMCX connectors | InfiniiVision series, EXR, Infiniium series |
Overview Keysight Active Probes - Single-Ended and Differential
Model Overview
Model | Type | Bandwidth | Attenuation | Input etc. | Recommended oscilloscopes (examples) |
▸1130B | Differential | 1.5 GHz | 10:1 | 50 kΩ/0.27...0.34 pf (differential), 25 kΩ/0.44...0.67 pF (single-ended), dynamic range ±2.5 V | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸1131B | Differential | 3.5 GHz | 10:1 | 50 kΩ/0.27...0.34 pf (differential), 25 kΩ/0.44...0.67 pF (single-ended), dynamic range ±2.5 V | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸1132B | Differential | 5 GHz | 10:1 | 50 kΩ/0.27...0.34 pf (differential), 25 kΩ/0.44...0.67 pF (single-ended), dynamic range ±2.5 V | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸1134B | Differential | 7 GHz | 10:1 | 50 kΩ/0.27...0.34 pf (differential), 25 kΩ/0.44...0.67 pF (single-ended), dynamic range ±2.5 V | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸1168B | Differential | 10 GHz | 3.45:1 | 50 kΩ/0.21 pf (differential), 25 kΩ/0.35 pF (single-ended), dynamic range 3.3 Vpeak-peak | Infiniium S series |
▸1169B | Differential | 13 GHz | 3.45:1 | 50 kΩ/0.21 pf (differential), 25 kΩ/0.35 pF (single-ended), dynamic range 3.3 Vpeak-peak | Infiniium S series |
▸DP0001A | Differential | 400 MHz | 50:1/100:1/250:1/500:1 | 10 MΩ/2 pF, 2000 V | 6000 X series, EXR series, Infiniium S serie |
▸DP0010A | Differential | 250 MHz | 17:1/85:1 | 1.7 MΩ/1.5 pF, ±4.2 V/±42 V | 6000 X series, EXR series, Infiniium S serie |
▸DP0011A | Differential | 500 MHz | 17:1/85:1 | 1.7 MΩ/1.5 pF, ±4.2 V/±42 V | 6000 X series, EXR series, Infiniium S serie |
▸DP0012A | Differential | 1 GHz | 17:1/85:1 | 1.7 MΩ/1.5 pF, ±4.2 V/±42 V | 6000 X series, EXR series, Infiniium S serie |
▸DP0013A | Differential | 1.7 GHz | 17:1/85:1 | 1.7 MΩ/1.5 pF, ±4.2 V/±42 V | 6000 X series, EXR series, Infiniium S serie |
▸DP0030A | Differential | 100 MHz | 250:1/25:1 | 5 MΩ/2 pF (differential), ±750 V (DC + AC peak) | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸DP0031A | Differential | 200 MHz | 250:1/25:1 | 5 MΩ/2 pF (differential), ±750 V (DC + AC peak) | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸DP0032A | Differential | 200 MHz | 500:1/50:1 | 10 MΩ/2 pF (differential), ±1500 V (DC + AC peak) | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸DP0033A | Differential | 200 MHz | 1000:1/100:1 | 20 MΩ/2 pF (differential), ±3000 V (DC + AC peak) | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸N2750A | Differential | 1.5 GHz | 2:1/10:1 | 0.7 pF/200 kΩ (differential), 100 kΩ (single-ended), 50 kΩ (common mode) | 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N2751A | Differential | 3.5 GHz | 2:1/10:1 | 0.7 pF/200 kΩ (differential), 100 kΩ (single-ended), 50 kΩ (common mode) | Infiniium S series |
▸N2752A | Differential | 6 GHz | 2:1/10:1 | 0.7 pF/200 kΩ (differential), 100 kΩ (single-ended), 50 kΩ (common mode) | Infiniium S series |
▸N2790A | Differential, CMRR -70 dB (500 VDC, -80 dB (50/60 Hz), -50 dB (at 1 kHz and 1 MHz) | 100 MHz | 50:1/500:1 | 7 pF/4 MΩ (input to GND), 3.5 pF/8 MΩ (between inputs); max. diff. operating voltage (DC+peak-AC or RMS) ±1400 V at 500:1, ±140 V at 50:1 | 3000 X series, 4000 X series |
▸N2795A | Single-ended | 1 GHz | 10:1 | 1 pF/1 MΩ ±8 V | 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N2796A | Single-ended | 2 GHz | 10:1 | 1 pF/1 MΩ ±8 V | 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N2797A | Single-ended, for extreme temperatur -40...+85°C | 1,5 GHz | 10:1 | 1 pF/1 MΩ ±8 V | 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N7020A | Power rail probe | 2 GHz | 1:1 | 50 kΩ, 0.7 pF | 3000 X series, 4000 X series, 6000 X series, EXR series, Infiniium S series |
▸N7024A | Power rail probe | 6 GHz | 1:1 | 50 kΩ, 0.7 pF | EXR series, Infiniium S series |
Overview Keysight Current Probes
Model Overview
Model | Type | Frequency range | Max. input current | Applications and remarks |
▸1146B | AC/DC current, 0.1 V/A (0...10 Apeak) or 0.01 V/A (0...100 Apeak) | 100 kHz | 100 Apeak | For AC line, motors, automotive current measurement; requires 9 VDC battery; high-impedance BNC input |
▸1147B | AC/DC current, 0.1 V/A | 50 MHz | 15 Apeak continuous, 30 Apeak non-continuous | Motors, switching power supplies, magnetic-device current measurements; high-impedance AutoProbe input compatible with 3000 X series, 4000 X series, 6000 X series |
▸N2780B | AC/DC current, 0.01 V/A | 2 MHz | 500 ARMS continuous, 700 Apeak non-continuous | Motors, switching power supplies, line currents; high-impedance BNC input; requires N2779A 3-channel power supply |
▸N2781B | AC/DC current, 0.01 V/A | 10 MHz | 150 ARMS continuous, 300 Apeak non-continuous | Motors, switching power supplies, transformers; high-impedance BNC input; requires N2779A 3-channel power supply |
▸N2782B | AC/DC current, 0.1 V/A | 50 MHz | 30 ARMS continuous, 50 Apeak non-continuous | Switching power supplies, amplifiers, magnetic devices; high-impedance BNC input; requires N2779A 3-channel power supply |
▸N2783B | AC/DC current, 0.1 V/A | 100 MHz | 30 ARMS continuous, 50 Apeak non-continuous | Switching power supplies, low current measurements; high-impedance BNC input; requires N2779A 3-channel power supply |
▸N2820A | AC/DC current, 2 channels, 300 V/A (zoom in) and 2 V/A (zoom out) | 3 MHz (zoom out), 500 kHz (zoom in) | Max. 5 A, min. 50 µA (with supplied accessories) | Capturing and analyzing low-level current flow in the DUT to characterize sub-circuits or measure current consumption of battery-powered devices or integrated circuits; compatible with InfiniiVision 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N2821A | AC/DC current, 1 channel, 300 V/A (zoom in) and 2 V/A (zoom out) | 3 MHz (zoom out), 500 kHz (zoom in) | Max. 5 A, min. 50 µA (with supplied accessories) | Capturing and analyzing low-level current flow in the DUT to characterize sub-circuits or measure current consumption of battery-powered devices or integrated circuits; compatible with InfiniiVision 3000 X series, 4000 X series, 6000 X series, Infiniium S series |
▸N2893A | AC/DC current; high S/N ratio, low current measurement capability | 100 MHz | 15 Apk, 15 ADC, 10 ARMS continuous, 30 Apk non-continuous | Easy protect function at excessive input; auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe; compatible with high impedance AutoProbe interface |
▸N7026A | AC/DC current, 1 V/A (high sensitivity) | 150 MHz | 30 ARMS continuous, 40 Apeak non-continuous | Motor, switching power supplies, magnetic device current measurements, high sensitivity current measurement (1 mA/Div); high-impedance AutoProbe input |
▸N7040A | Rogowski AC current, 2 mV/A | 3 Hz...23 MHz | 3,000 Apeak | Motor, switching power supplies, double pulse tester current measurements; high-impedance BNC input |
▸N7041A | Rogowski AC current, 10 mV/A | 12 Hz...30 MHz | 600 Apeak | Motor, switching power supplies, double pulse tester current measurements; high-impedance BNC input |
▸N7042A | Rogowski AC current, 20 mV/A | 9.2 Hz...30 MHz | 300 Apeak | Motor, switching power supplies, double pulse tester current measurements; high-impedance BNC input |
Overview Keysight Fiber-Isolated Probes
Model Overview
Model | Description | Bandwidth | Available Probe Tips |
▸PS0004A | Optically isolated differential probe, 2 m, AutoProbe 1 interface; cable type: Optical fiber bundle; overvoltage and measurement category per IEC -61010-0312: Non-CAT (mains isolated); safety certification: UL-certified; output drive: 50 Ω | 350 MHz |
|
▸PS0006A | 700 MHz | ||
▸PS0008A | 1 GHz |
Information on product safety:
Manufacturer:
Keysight, 1400 Fountaingrove Parkway, Santa Rosa, CA/USA
www.keysight.com
(Keysight Technologies Deutschland GmbH)