Siglent ODP6000B Series Opto-Isolated Differential Probe

New
Scaled Prices
starting 173,00
excluding VAT plus shipping
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Files/Downloads

Siglent ODP6000B Series Opto-Isolated Differential Probe

The Siglent ODP6000B series are optical isolated voltage probes with remarkably high CMRR. The CMRR of traditional differential probe decreases fast in high-frequency range, as a result, measuring the small voltage signal waveform (e.g., the driving voltage when measuring the upper MOSFET of the half-bridge circuit) under high CM interference voltage accurately become an extremely hard task. ODP6000B series applies optical isolation technologies and gains remarkably high CMRR in all working bandwidth.

  • 2 chargeable batteries that can be replaced to keep the probe work continuously.
  • Can be calibrated and zeroed online without disconnecting from the tested equipment.
  • Multiple attenuators available, able to meet the measurement requirement of different voltage.
  • Extremely high CMRR.
  • Bandwidth over 1 GHz.
  • Isolation voltage over 60 kV.
  • High accuracy and stability in wide temperature range.
  • Smaller size.
  • Application: R&D, debugging or maintenance of switching power supply, motor driver, new energy inverter, converter, LED power supply, household appliances and other electrical power devices, floating signal test, measure the gate voltage drive of power devices like Si/SiC/GaN, small signal measurement of differential mode under high common mode voltage.

Model Overview

ModelDescription
ODP6050BOptical isolated differential probe500 MHz, 50X, max. differential test voltage (DC + peak AC) ±25 V, isolated voltage ±60 kVDC 5 V adaptor or 7.4 V battery power supplyStandard 50X/1000X/2000X/5000X attenuator
ODP6100BOptical isolated differential probe1 GHz, 50X, max. differential test voltage (DC + peak AC) ±25 V, isolated voltage ±60 kVDC 5 V adaptor or 7.4 V battery power supplyStandard 50X/1000X/2000X/5000X attenuator
Attenuator modelConnector typeAttenuation ratioMeasurement rangeInput impedance
CK-AT5X-2SSMB5:1±2.5 Vpeak1 MΩ || 28 pF
CK-AT10X-2SSMB10:1±5 Vpeak1 MΩ || 6 pF
CK-AT20X-2SSMB20:1±10 Vpeak5 MΩ || 6 pF
CK-AT50X-2SSMB50:1±25 Vpeak10 MΩ || 4 pF
CK-AT100X-2SSMB100:1±50 Vpeak10 MΩ || 2 pF
CK-AT200X-2SSMB200:1±100 Vpeak10 MΩ || 2 pF
CK-AT500X-2SSMB500:1±250 Vpeak10 MΩ || 2 pF

Included: Optical isolated differential probe ODP 6050B or 6100B, 1x 50X attenuator (CK-AT50X-2), 2x SSMB male socket to DuPont cable connector (CK-321), 10x SSMB male socket (CK-23), 1x USB power supply cable Type-C 1.5 m (CK-314A), 2x power supply adaptor 5 V/2 A (CK-605), 1x OE transmitter support frame (CK-690A), 1x BNC male to SSMB male (CK-25), 3x input extension cable (CK-322), 1x output extension cable (CK-325), 1x battery charger set (CK-691), 1x instruction manual, 1x warranty card, 1x test report.


Information on product safety:

Manufacturer:
SIGLENT Technologies CO., LTD., Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101/CHN
www.siglent.com
(EU branch Germany)