CableEye HVX(-21) High Voltage/HVX Cable Tester, 152/512/1024 Testpoints, USB

starting 10.702,86
including VAT free shipping (Germany)
min Quantity
1 piece
Unit price
base price
Variants
technical Question?
recommend by email
close
Please fill in all fields.
Question Type
Your E-mail Adress
My Question:
Please validate that you are not a robot.
Description
Accessories
Files/Downloads

Benefits of the High-Voltage Cable Testing System CAMI CableEye HVX/HVX-21 (CAMI-829/CAMI-829A)

  • Combines the features of CableEye low voltage testers with additional testing functions for higher voltages.
  • Tests isolation resistance with selectable voltages up to 1500 VDC/1000 VAC or 2100 VDC/1200 VAC
  • Expandable for even more complex cables and cable harnesses.

CAMI CableEye HVX(-21) High Voltage/HVX Cable Tester: 152 Testpoints, Expandable to 512/1024, USB

With the CableEye test system you can easily test any cable or cable harnesses with your PC, for example for continuity, open wires, short circuits or miswiring. The CableEye cable tester is particularly suitable for cable production, research and development, maintenance, network technology and prototyping as well as for everyday testing in industry, event technology etc. With different connector boards and a flexible software for Windows the system "learns" your cables and then tests them. Choose from a wide variety of plug-on connector boards to mate with most standard cables, and easily mount custom connectors for unusual applications. The HVX versions allow the test of cables with higher voltages.

  • CableEye HVX(-21) (CAMI-829A)- the high voltage/HVX test system for 128 test points, expandable to 512/1024.
  • Store full cable documentation.
    Print out cable wiring diagrams.
    Print labels.
    Log and print error protocols.
  • Visualize cable wiring: Automatically draw schematics from measured cable connections. Compare cables.
    Easy testing of cable leads.
  • Plug-in connector boards, easy to install, for various connector types like BNC, RJ45, D-sub, ribbon cable/IDC and many more.
  • Connects to the PC via USB.
  • Easy-to-use Windows software. Can be set up for one-button operation to speed production testing. Unskilled operators need only to press the TEST pushbutton on the fixture to trigger an involved test sequence set up by the quality control engineer, with results automatically logged to disk for later analysis and report generation.
  • Continuity test:
    Detects open lines, short circuits and miswired cables.
    Pass/fail test with a 'known good' sample.
    Locate intermittent connections and identify their position in the cable.
  • Resistance measurement:
    Testing of resistors integrated in the cable, e.g. termination, pullup/pulldown (depending on model).
    Test of diode orientation.
  • High voltage testing:
    Combines the CableEye LV tester with a high voltage module to provide insulation resistance and dielectric breakdown testing, adjustable in 1 V increments from 10 V to the maximum voltage permitted.
    The HVX model tests up to 1500 VDC/1000 VAC or 2100 VDC/1200 VAC (resistance 0.1 Ω...1 GΩ or 5 GΩ).
    Ramp up, ramp down, dwell time (same as test time), trip current, and trip delay (same as soak time) may be programmed for your specific requirements.

CableEye Systems - Technical Specifications

ModelHigh voltage test - HVX - CAMI-829High voltage test - HVX-21 - CAMI-829
Control module test points128 + 24 accessory test points for LV tests, 128 for HV tests128 + 24 accessory test points for LV tests, 128 for HV tests
Max. test points1024512
Test time (128 test points) - continuity onlyFrom 0.20/0.15 sFrom 0.20/0.15 s
Test time (128 test points) - with resistance testFrom 0.25/0.40 sFrom 0.25/0.40 s
Resistance thresholds0.1/0.02 Ω...1 GΩ0.1/0.02 Ω...5 GΩ
Resistance accuracy - 10 MΩ...100Ω±0.2 Ω/±0.15 Ω±0.2 Ω/±0.15 Ω
Resistance accuracy - 100 MΩ...1 MΩ1...5% (1...100 MΩ)1...5% (1...100 MΩ)
Resistance accuracy - full rangeLesser accuracy above 100 MΩLesser accuracy above 100 MΩ
Resistance Range0.1/0.02 Ω...5/6 MΩ0.1/0.02 Ω...5/6 MΩ
4-Wire Kelvin1 mΩ ±1 mΩ (1 mΩ...15 Ω, test current 100 mA...1 A) - optional feature (item 832)1 mΩ ±1 mΩ (1 mΩ...15 Ω, test current 100 mA...1 A) - optional feature (item 832)
Intermittent connection scan rate90 Scans/s - 64 test points, 47 Scans/s - 64 test points90 Scans/s - 64 test points, 47 Scans/s - 64 test points
Diode measurementOrientation, forward voltage and reverse breakdown >10 VOrientation, forward voltage and reverse breakdown >10 V
Test voltage10...1500 VDC or 10...1000 VACRMS in increments of 1 V10...2100 VDC or 10...1200 VACRMS in increments of 1 V
Test voltage accuracyDC: ±2%, ±1.5 V; AC: ±4%, ±2 VRMSDC: ±2%, ±1.5 V; AC: ±4%, ±2 VRMS
Max. test current3.3 mA3.3 mA
Capacitance range100 pF...100 mF - optional feature (item 833)100 pF...100 mF - optional feature (item 833)
Capacitance accuracy±5% - optional feature (item 833)±5% - optional feature (item 833)
Capacitance measurement rate20 Meas./s at 100 nF or less - optional feature (item 833)20 Meas./s at 100 nF or less - optional feature (item 833)
Twisted pair measurementYes, 182.9 m/6 ft min. length - optional feature (item 833)Yes, 182.9 cm/6 ft min. length - optional feature (item 833)
Measurement cable lengthMin. length 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833)Min. length 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833)
Measurement distance to breakMin. distance to break 182.9 cm/6 ft, ±91.4 cm/3 ft - optional feature (item 833)Min. distance to break 182.9 cm/6  ft, ±91.4 cm/3 ft - optional feature (item 833)
Dwell time rangeLV: 1 µs...100 ms; HV: 30 ms...300 sLV: 1 µs...100 ms; HV: 30 ms...300 s
Insulation resistance measurement2 MΩ...1 GΩ at 1500 VDC; 2 MΩ (min.) at 1000 VAC; current sensitivity: 1 µA2 MΩ...5 GΩ at 100 VDC; 2 MΩ (min.) at 1200 VAC; current sensitivity: 0.2 µA
Digital-I/OsPairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765)Pairs of test points used as inputs, 50+ relay outputs with optional relay boards (item 765)
CalibrationRecommended yearlyRecommended yearly
Test point connectors64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module64-pin dual-row headers, 2.54 mm/0.1" centers; two per 128-point module
Remote control socketYes, MiniDIN8 Connector for use with e.g. footswitch, external control panelYes, MiniDIN8 Connector for use with e.g. footswitch, external control panel
Probe socketYes; probe included with tester; accessory port also usable with minihook cablesYes; probe included with tester; accessory port also usable with minihook cables
Power requirement100...250 VAC, 50...60 Hz/130 W (max.) for 128 test points; 175 W (max.) for 512 test points; IEC-standard universal C14 chassis plug100...250 VAC, 50...60 Hz/130 W (max.) for 128 test points; 175 W (max.) for 512 test points; IEC-standard universal C14 chassis plug
Weight9.5 kg9.5 g
Computer requirementsAny Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCsAny Windows-capable machine running Windows 7 or later; compatible with touchscreen and laptop PCs
USB interfaceUSB 1.1, fast, two portsUSB 1.1, fast, two ports
ModelHigh voltage test - HVX - CAMI-829High voltage test - HVX-21 - CAMI-829
ContinuityOpens, shorts, miswiresOpens, shorts, miswires
Intermittent faultsIntermittent faults
Complex networks, backplanesComplex networks, backplanes
ResistanceConnection, non-Connection qualityConnection, non-Connection quality
Resistance (2-wire)Resistance (2-wire)
Continuous resistance scanContinuous resistance scan
Fixture resistance nullingFixture resistance nulling
Option: Resistance (4-wire Kelvin)Option: Resistance (4-wire Kelvin)
Option: High current resistanceOption: High current resistance
CapacitanceOption: Wire length, cable lengthOption: Wire length, cable length
Option: Length to breakOption: Length to break
Option: Twist pairingOption: Twist pairing
Single channel safety testChassis, panels, transformers, etc.Chassis, panels, transformers, etc.
Insulation qualityDielectric strength, withstand voltageDielectric strength, withstand voltage
Insulation resistanceInsulation resistance
Presence of contaminantsPresence of contaminants
In-Line ComponentsResistorsResistors
Diodes - orientationDiodes - orientation
Diodes - forward voltageDiodes - forward voltage
LEDs - orientationLEDs - orientation
LEDs - color detectionLEDs - color detection
Zener diodes - orientationZener diodes - orientation
Zener diodes - forward voltageZener diodes - forward voltage
Zener diodes - reverse breakdown voltage <10 VZener diodes - reverse breakdown voltage <10 V
Zener diodes - reverse breakdown voltage >10 VZener diodes - reverse breakdown voltage >10 V
Option: CapacitorsOption: Capacitors

CableEye, All Models and Expansions

Low Voltage Testing
▸CAMI-814CableEye M2ZBasic system/entry level128 test points, not expandable. USB interface
▸CAMI-826CableEye M3ZEnhanced system 1152 test points, expandable to 2560. Can also measure resistance (0.1 Ω...5 MΩ) and diodes. USB interface
▸CAMI-824CableEye M4Enhanced system 2152 test points, expandable to 2560. Can also measure resistance (0.02 Ω...6 MΩ), diodes, capacitance, twisted-pairing. USB interface
Low Voltage Testing Expansion Modules
▸CAMI-827M3Z-AEXExpansion module for the M3Z system (826), stackable version. 128 additional test points. Use more modules to expand the CableEye systems up to 2560 test points). Connected to the base system via ribbon cables.
▸CAMI-825M4-AEXExpansion module for the M4 system (824), stackable version. 128 additional test points. Use more modules to expand the CableEye systems up to 2560 test points). Connected to the base system via ribbon cables.
High Voltage Testing
▸CAMI-829CableEye HVXHVX systemApplies voltage up to 1500 VDC/1000 VAC, measures resistance between 0.1 Ω and 1 GΩ, 128 test points, expandable to 1024
▸CAMI-829ACableEye HVX-21Enhanced HVX systemApplies voltage up to 2100 VDC/1200 VAC, measures resistance between 0.1 Ω and 5 GΩ, 512+ test points
High Voltage Testing Expansion Modules
▸CAMI-828HVX-AEXExpansion module for HVX/CAMI-829: Adds 128 testpoints.
▸CAMI-828HVX-21-AEXExpansion module for HVX-21/CAMI-829A: Adds 128 testpoints.

CableEye is a modular system. A variety of optionens and connector boards are available. The webshop only shows a selection. Contact us for individual configurations or special connector board designs. Find a CB board compatibility chart and other overviews ▸here.

CAMI CableEye cable tester

starting 473,62